Desa Tech CSBNT, CSPINT, CSBPT, CSPIPT, CSPBPT, CSPBNT Gas leak. See Warning, Statement at top

Models: CSPBPT CSPINT CSPIPT CSBPT CSBNT CSPBNT

1 24
Download 24 pages 12.15 Kb
Page 18
Image 18

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These

fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

Heater produces a clicking/tick-

1.

Metal expanding while heating

1.

This is common with most heat-

ing noise just after burner is lit

 

or contracting while cooling

 

ers. If noise is excessive, contact

or shut off

 

 

 

qualified service person

 

 

 

 

 

Heater produces unwanted

1.

Heater burning vapors from

1.

Open window and ventilate

odors

 

paint, hair spray, glues,

 

room. Stop using odor caus-

 

 

cleaners, chemicals, new

 

ing products while heater is

 

 

carpet, etc. (See IMPOR-

 

running

 

 

TANT statement above)

 

 

 

2.

Gas leak. See Warning

2.

Locate and correct all leaks

 

 

statement at top of

 

(see Checking Gas Connec-

 

 

page

 

tions, page 11)

 

 

 

 

 

Heater shuts off in use (ODS

1.

Not enough fresh air is

1.

Open window and/or door for

operates)

 

available

 

ventilation

 

2.

Low line pressure

2.

Contact local natural or pro-

 

3.

ODS/pilot is partially

 

pane/LP gas company

 

3.

Clean ODS/pilot (see Cleaning

 

 

clogged

 

and Maintenance, page 14)

 

 

 

 

 

Gas odor even when control knob

1.

Gas leak. See Warning

1.

Locate and correct all leaks

is in OFF position

 

statement at top of

 

(see Checking Gas Connec-

 

 

page

 

tions, page 11)

 

2.

Control valve defective

2.

Replace control valve

Gas odor during combustion

1.

Foreign matter between con-

 

 

trol valve and burner

 

2.

Gas leak. See Warning

 

 

statement at top of

 

 

page

1.Take apart gas tubing and remove foreign matter

2.Locate and correct all leaks (see Checking Gas Connec- tions, page 11)

18