Blanco BCGC74 - BCGC52 Manual ignition, Electrical ignition, How To Use The Burners, Warnings

Models: BCGC74 - BCGC52

1 15
Download 15 pages 24.25 Kb
Page 3
Image 3
1) BURNERS

USE

1) BURNERS

A diagram is screen-printed above each knob on the front panel. This diagram indicates to which burner the knob in question corresponds. After having opened the gas mains or gas bottle tap, light the burners as described below:

- Manual ignition

Push and turn the knob corresponding to the required burner in an anticlockwise direction until it reaches the full on position (large flame fig. 1), then place a lighted match near the burner.

- Electrical ignition

Push and turn the knob corresponding to the required burner in an anticlockwise direction until it reaches the full on position (large flame fig. 1), then depress and release the ignition button.

- Automatic electrical ignition

Push and turn the knob corresponding to the required burner in an anticlockwise direction until it reaches the full on position (large flame fig. 1), then depress the knob.

-Lighting burners equipped with flame failure device

The knobs of burners equipped with flame failure device must be turned in an anticlockwise direction until they reach the full on position (large flame fig. 1) and come to a stop. Now depress the knob in question and repeat the previously indicated operations.

Keep the knob depressed for about 10 seconds once the burner has ignited.

Note: you are advised not to try and light a burner if the flame divider (Burner Cap) is not correctly placed. In the event of burner flames being accidentally extinguished, turn off the burner control and do not attempt to re-ignite the burner for at least 1 minute.

HOW TO USE THE BURNERS

In order to achieve maximum efficiency with the least possible gas consumption:

-Use adequate pans for each burner (consult the following table and fig. 2).

-When the pan comes to the boil, set the knob to the reduced rate position (small flame fig. 1).

-Always place a lid on the pans.

Burners

Power ratings

 

Pan Ø in cm

 

Natural

U-LPG

 

Ultra rapid

11.9

MJ

11.9

MJ

22 ÷ 28

Semirapid

6.3 MJ

6.3 MJ

16 ÷ 18

Auxiliary

3.6

MJ

3.6

MJ

10 ÷ 14

WARNINGS:

-Burners with flame failure device may only be ignited when the relative knob has been set to the Full on position (large flame fig. 1).

-Matches can be used to ignite the burners in a blackout.

-Never leave the appliance unattended when the burners are being used. Make sure there are no children in the near vicinity. Particularly make sure that the pan handles are correctly positioned and keep a check on foods requiring oil and grease to cook since these products can easily catch fire.

-Do not spray aerosols in the vicinity of this appliance while it is in operation.

-This appliance is not to be installed in marine craft. Where this appliance is installed in a caravan, it shall not be used as a space heater.

-Do not store or use flammable liquids or items in the vicinity of the hotplate.

FIG. 1

FIG. 2

3

Page 3
Image 3
Blanco BCGC74 - BCGC52 Burners, Manual ignition, Electrical ignition, Automatic electrical ignition, Power ratings, U-Lpg