Blanco BCGC74 - BCGC52 warranty Conversions, 9U-LPGTO NATURAL GAS CONVERSION PROCEDURE, Burner

Models: BCGC74 - BCGC52

1 15
Download 15 pages 24.25 Kb
Page 10
Image 10
CONVERSIONS

CONVERSIONS

9)U-LPG TO NATURAL GAS CONVERSION PROCEDURE

Appliance models: Gas crystal glass hotplate models:

BCGC74 4 Burners

BCGC52 2 Burners

1.Remove each burner cap and burner skirt.

2.Remove the U-LPG main injector with a

7mm/VF tube spanner and replace with the appropriate size Natural Gas main injector for each burner. The following injector sizes are required for Natural Gas:

Burner

Main injector

Wok

1.55 mm

Semi Rapid

1.12 mm

Auxiliary

0.85 mm

10)NATURAL GAS TO UNIVERSAL LPG CONVERSION PROCEDURE

Appliance models: Gas crystal glass hotplate models:

BCGC74 4 Burners

BCGC52 2 Burners

1.Remove each burner cap and burner skirt.

2.Remove the Natural Gas main injector with a

7mm/VF tube spanner and replace with the appropriate size U-LPG main injector for each burner. The following injector sizes are required for U-LPG:

Burner

Main injector

Wok

0.95 mm

Semi Rapid

0.70 mm

Auxiliary

0.53 mm

3.Shut off gas supply to the appliance.

4.Disconnect gas inlet pipe from the U-LPG Gas test point inlet fitting.

5.Remove the U-LPG test point inlet fitting from the appliance.

6.Fit the Natural Gas Regulator supplied in the conversion kit.

7.Connect the gas supply to the Regulator.

8.Check for gas leaks. Do not use a naked flame to check for gas leaks.

9.Adjust the gas pressure to 1.00 kPa.

10.Remove the control knob, with a thin shaft blade screwdriver down the centre of each gas valve shaft, screw the by-pass injector anti-clockwise. Test the appliance on both high and low flame for each burner. If the burner fails to remain alight or the flame is not stable on the simmer setting, adjust the by-pass screw, until flame is stable.

11.If not already removed, remove the “Only for use with U-LPG” label adhered to the bottom panel near the gas connection.

3.Remove the control knob, with a thin shaft blade screwdriver down the centre of each gas valve shaft, screw the by-pass injector fully clockwise.

4.Shut off gas supply to the appliance.

5.Disconnect gas inlet pipe from the Natural Gas Regulator.

6.Remove the Natural Gas Regulator from the appliance.

7.Fit the U-LPG test point inlet fitting supplied in the conversion kit.

8.Connect the gas supply to the inlet fitting.

9.Check for gas leaks. Do not use a naked flame to check for gas leaks.

10.Adjust the gas pressure to 2.75 kPa.

11.Test the appliance on both high and low flame for each burner and check the gas pressure. If the burner fails to remain alight or the flame is not stable on the simmer setting, adjust the by-pass screw until flame is stable.

12.If not already removed, remove the “Only for use with Natural Gas” label adhered to the bottom panel near the gas connection.