5) LOCATION AND VENTILATION

INSTALLATION

5) LOCATION AND VENTILATION

Ventilation must be in accordance with AS5601/AG601–GasInstallations.

In general, the appliance should have adequate ventilation for complete combustion of gas, proper flueing and to maintain temperatureofimmediatesurroundingswithinsafelimits.

The wall and bench surfaces must be capable of sustaining temperaturesof75°C.

All laminates, fixing adhesive and surfacing materials should becertifiedsuitableforthistemperature.

6) GAS CONNECTION

This gas connection is male 1/2” BSP and is situated at the rear of the appliance, 415 mm from the right hand side and 55 mm from the rear of the cooktop.

A. The hotplate can be connected with rigid pipe as specified in AS5601 table 3.1.

B. If installing with a hose assembly, install with a hose assembly that complies with AS/NZS 1869 (AGA Approved), 10mm ID, class B or D, no more than 1.2m long and in accordance with AS5601. Ensure that the hose does not contact the hot surfaces of the hotplate, oven, dishwasher or any other appliance that may be installed underneath or next to the hotplate. The hose should not be subjected to abrasion, kinking or permanent deformation and should be able to be inspected along its entire length with the cooktop in the installed position.

Unions compatible with the hose fittings must be used and all connections tested for gas leaks.

The gas supply connection for the hose assembly must be accessible.

Natural Gas

Natural Gas installations require the connection of a gas regulator at the appliance. This regulator is supplied with the appliance on purchase.

Assemble the regulator (noting the gas flow direction) and transition pieces (supplied with the appliance), in accordance with figure 10.

The transition piece on the supply side of the regulator must be provided by the installer.

The appliance is factory set for Natural Gas. The test point pressure should be adjusted to 1.00 kPa with the wok burner operating at maximum.

Liquified Petroleum Gas

In a Universal LPG installation the gas regulation is made at the gas cylinder and regulation at the appliance is not required. The supply pressure should be 2.75 kPa. To connect supply to the appliance use transition pieces as shown in figure 11. These pieces are supplied with the appliance on purchase.

WARNING:

THE BURNER FLAME MUST BE ADJUSTED BY THE INSTALLER.

FAULTY INSTALLATION WILL NOT BE COVERED UNDERWARRANTY.