Blanco BCGC74 - BCGC52 warranty Burner Arrangement On The Hot Plate Table, Conversions

Models: BCGC74 - BCGC52

1 15
Download 15 pages 24.25 Kb
Page 11
Image 11
BURNER ARRANGEMENT ON THE HOT PLATE

CONVERSIONS

BURNER ARRANGEMENT ON THE HOT PLATE

TABLE

 

BURNERS

 

GAS

NORMAL

INJECTOR

NOMINAL HEAT

 

BY

 

 

 

 

 

PRESSURE

DIAMETER

INPUT (MJ/h)

 

 

 

 

 

 

 

PASS

 

DESCRIPTION

 

 

(kPa)

(1/100 mm)

MAX.

 

(1/100 mm)

1

ULTRA RAPID

 

U-LPG

2.75

95

 

11.9

85

 

 

NATURAL

1.00

155

 

11.9

85

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

SEMIRAPID

 

U-LPG

2.75

70

 

6.3

 

32

 

 

NATURAL

1.00

112

 

6.3

 

32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

AUXILIARY

 

U-LPG

2.75

53

 

3.6

30

 

 

NATURAL

1.00

85

 

3.6

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIG. 14