Operation

7.Reverse tip to UNCLOG position. Put prime/pres- sure relief valve DOWN to spray position and trigger sprayer through tip into waste area for 1- 2 seconds.

ti19370a ti19346a

ti19366a

8.Engage trigger lock and put prime/pressure relief valve UP to release pressure.

ti19347a

ti19350a

9.Remove material cup.

10.Disengage trigger lock, put prime/pressure relief valve DOWN to spray position, hold sprayer slightly above material cup and pull trigger to discharge fluid from pump.

ti19403a

11.Put prime/pressure relief valve UP and pull trigger to finish flushing material.

ti19401a

12. Properly discard any material in cup.

Install/Service Filter (if needed)

1.Perform Pressure Relief Procedure, page 9.

2.Unthread front valve housing from sprayer.

ti19362a

3.Filter should come out of pump housing with valve. If filter remains in housing, remove it by hand or with pliers if necessary.

ti19342a

4. Install properly-sized filter (if needed).

ti19349a

5. Reassemble valve housing to pump.

ti19364a

3A2308C

13

Page 13
Image 13