Troubleshooting

Troubleshooting

 

 

 

 

 

 

 

 

 

Check everything in this Troubleshooting Table before

 

 

 

 

 

 

 

 

 

 

 

 

you bring the sprayer to an authorized service center.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Problem

Cause

Solution

 

 

 

 

 

 

Sprayer makes no sound when

Trigger is locked.

Disengage trigger lock. See page 9.

trigger is pulled

 

 

 

Status Indicator Light is solid YELLOW

Replace with charged battery and

 

 

 

 

 

 

 

 

 

 

when triggering, indicating that the bat-

place old battery in charger, or allow

 

 

 

 

 

tery charge is low, or the battery is too

battery to warm up.

 

 

 

 

 

cold.

 

 

 

 

 

 

 

 

 

 

 

 

 

Status Indicator Light is solid RED

Allow battery to cool.

 

 

 

 

 

when triggering, indicating that the bat-

 

 

 

 

 

 

tery is too hot to operate.

 

 

 

 

 

 

 

 

 

 

 

 

 

Battery is not installed or is damaged.

Install battery or replace.

 

 

 

 

 

 

 

 

 

 

 

 

Prime/Pressure Relief valve is in UP

Put valve DOWN to spray position.

 

 

 

 

 

position.

 

 

 

 

 

 

 

 

 

 

 

 

 

Tip is not in SPRAY position.

Turn tip to SPRAY position.

 

 

 

 

 

 

 

 

 

 

 

 

Pump is clogged, frozen, or has debris

See Repair manual.

 

 

 

 

 

inside.

 

 

 

 

Sprayer makes sound but no material

Sprayer is not primed or air is in

Prime the pump. See Starting a new

is sprayed when trigger is pulled

material cup.

Job (or Refilling the Cup), page 12.

 

 

 

 

 

 

 

 

 

 

 

 

Tip is clogged.

See Unclogging Tip/Guard

 

 

 

 

 

 

 

Assembly, page 18.

 

 

 

 

 

 

 

 

 

 

 

 

Tip filter is clogged.

Remove and clean tip filter. See

 

 

 

 

 

 

 

Install/Service Filter, page 13.

 

 

 

 

 

 

 

 

 

 

 

 

No or low material in liner.

Refill liner with material and prime the

 

 

 

 

 

 

 

pump.

 

 

 

 

 

 

 

 

 

 

 

 

Inlet ball is stuck from material

Use a pencil or thin rod to lightly push

 

 

 

 

 

residue left in sprayer.

on inlet valve to make sure it moves up

 

 

 

 

 

 

 

and down freely.

 

 

 

 

 

 

 

 

 

 

 

 

Outlet ball is stuck from material resi-

Use a thin rod to lightly push outlet

 

 

 

 

 

due left in sprayer.

valve ball to make sure it moves freely.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outlet valve is visible when filter is

 

 

 

 

 

 

 

removed. See Install/Service Filter,

 

 

 

 

 

 

 

page 13.

 

 

 

 

 

 

 

 

 

 

 

 

Pressure setting too low.

Turn pressure control knob clockwise

 

 

 

 

 

 

 

to increase pressure.

 

 

 

 

 

 

 

 

24

3A2308C

Page 24
Image 24
Graco 16N656, 16H960, 16N655 Troubleshooting, Job or Refilling the Cup, See Unclogging Tip/Guard, Install/Service Filter