| Troubleshooting |
|
|
|
|
Problem |
| Cause | Solution |
|
|
|
|
|
|
|
|
Paint leaks from bottom of pump |
| Piston seal failure. | Replace pump module. See Repair |
module. |
|
| manual. |
|
|
|
|
|
|
| Replace piston seals. See Repair |
|
|
| manual. |
|
|
| |
Water or thin cleaning fluids drip from | Thin fluids commonly drip while | After storage, the piston seals need | |
bottom of pump module. |
| spraying at high pressure. | to be energized prior to next use to |
|
|
| prevent leakage. To energize, follow |
|
|
| steps below: |
|
|
| a. Prime system with flushing fluid. |
|
|
| b. Spray at low pressure setting “1” |
|
|
| for 10 seconds. |
|
|
| c. Drain fluid. You are now ready to |
|
|
| spray. |
|
|
| |
Cannot squeeze bag to extinguish air | Lightly poke bottom of check valve on | ||
out of liner with a new lid. |
|
| underside of lid to release valve. |
|
|
|
|
|
| Replace lid. | |
|
| solvents. |
|
|
|
|
|
|
| Check valve is frozen from cured | Replace lid. |
|
| material. |
|
|
|
| |
Sprayer shuts down after 1.5 seconds | Pressure is too high. | Turn pressure control knob counter- | |
of spraying and yellow light flashes. |
| clockwise. | |
|
|
|
|
|
|
| Increase tip size. |
|
|
| |
Liquid is squirting out of accumulator. | Accumulator is worn out. | Replace accumulator. | |
|
|
| |
Spray Pattern Diagnostics |
| ||
|
|
|
|
Problem |
| Cause | Solution |
|
| ||
|
| ||
Spray pattern is pulsating: | Operator is moving too fast while spraying. Slow speed of movement. |
|
| Tip or tip filter is clogged. | Unclog tip or clean tip filter, page 18. |
|
|
|
|
Spray pattern has tails: | Pressure control is too low. | Turn up pressure control. | |
|
| Incorrect tip for application of | Change tip. |
|
| material. |
|
|
|
|
|
|
| Inlet or outlet valves are worn. | See Repair manual. |
ti15526a |
|
|
26 | 3A2308C |