Repair
Clamshell
Removal
1.Engage trigger lock and put prime/pressure relief valve in UP position to relieve pressure.
ti19347a ti19350a
2. Remove material cup and battery.
6.Remove nut from ground stud. Remove ring termi- nal and unscrew second nut from ground stud. Remove ground stud from clamshell.
ti19638a
7.Carefully remove motor, motor housing, switch, con- trol board, indicator lights, trigger lock, and static wick from clamshell.
ti19360a
ti19617a
ti19639a
3.Remove pump module from drive module. See Pump Module/Drive Module, page 31.
4.Remove screws (42) from motor housing.
42
ti19636a
5.Remove screws (43) from clamshell.
43
ti19637a
Installation
1. Insert control board into right half of clamshell.
ti19627a
2.Install two LED lights into designated slot in right half of clamshell. Push wire bundle into slots in clamshell.
ti19628a
3A2308C | 33 |