3.Set motor housing into right half of clamshell and loosely install two bolts (42) to motor housing as shown below.

42

Repair

7.Install ground terminal to stud and tighten second nut onto stud. Install wire up along handle.

ti19629a

4. Route wires from motor down the handle.

ti19630a

5.Assemble trigger over top of wires. Route trigger wires behind trigger.

ti19631a

6. Insert trigger lock over trigger with o-ring facing out.

ti19632a

ti19641a

8.Insert static wick into right half of clamshell and install left clamshell to right clamshell.

ti19634a

NOTICE

Wires can become damaged when pinched between clamshell halves. Make sure no wires are pinched during reassembly.

9.Install two bolts (42) to motor housing and install screws (43) to connect clamshell halves. Make sure LED lights and static wick are securely in place. Tighten bolts (42) to 50 in-lb (5.6 N•m) and screws (43) to 9 in-lb (1 N•m).

43

42

ti19635a

10.Install pump module into drive module. See Pump Module/Drive Module, page 31.

36

3A2308C

Page 36
Image 36
Graco 16N655, 16H960, 16N927, 16N654, 16N656 important safety instructions Ti19632a Ti19641a