Install Tip/Guard Assembly (if not installed)

NOTE: Only use Graco Tip/Guard assemblies.

This equipment stays pressurized until pressure is manually relieved. To help prevent serious injury from pressurized fluid, such as skin injection, splashing fluid and moving parts, follow the Pressure Relief Procedure when you stop spraying and before cleaning, checking, or servicing the equipment.

1.Engage trigger lock and put prime/pressure relief valve UP to relieve pressure.

ti19350a

ti19347a

Do NOT place hands in front of tip.

2.Screw Tip/Guard Assembly onto sprayer. Tighten retaining nut until completely engaged with sprayer. Do not overtighten nut.

ti19369a

Filling and Installing Cup

1.Engage trigger lock and put prime/pressure relief valve UP to relieve pressure.

Operation

2. Install liner into material cup and fill with material.

ti19348a

3.Thread lid onto material cup and connect cup to sprayer. NOTE: Do not squeeze sides of cup while threading lid onto cup.

ti19354a

ti19384a

NOTE: Check valve can be oriented in three loca- tions when attached to cup. If squeezing liner with left hand, position check valve on left side. If squeezing liner with right hand, position check valve on right side.

ti19355a

4.Squeeze liner to purge air through check valve until material is present at check valve.

 

 

ti19367a

ti19350a

ti19347a

NOTE: To purge the maximum amount of air out of

 

 

the liner, slightly tilt the sprayer so the check valve is the highest point.