Operation

Shutdown and Cleaning

NOTICE

Failure to properly clean sprayer after each use will result in hardened materials, damage to the sprayer, and the warranty will no longer be valid. Do not store solvents other than mineral spirits in sprayer.

Flushing Sprayer

Do not spray solvents through the spray tip. Clean the tip in a bucket of compatible solvent.

Keep spray area well-ventilated. Keep a good supply of fresh air moving through the area.

NOTICE

Protect the internal parts of this sprayer from water.

Do not submerge the sprayer in cleaning fluid. Openings in shroud allow cooling of mechanical parts and electron- ics inside. If water or cleaning fluid gets into these open- ings, the sprayer could malfunction or become permanently damaged.

1.Engage trigger lock and put prime/pressure relief valve UP to release pressure.

ti19347a ti19350a

ti14994a

2. Turn pressure control knob to prime/clean position.

ti19357a

3. Remove cup from sprayer.

ti19360a

4. Remove lid from cup.

ti19363a

5.Remove material liner and lid from cup and properly dispose. Properly dispose any excess material left in the liner.

ti19352a

6.Insert a new liner into cup and fill 1/2 full with appro- priate flushing fluid. Screw on lid and attach cup to sprayer. Shake sprayer to move flushing fluid around and clean all wetted areas inside cup.

ti19365a

3A2308C

19

Page 19