Image 6
Pressure Testing Heater Gas Connections

SETUPBATTERY INSTALLATION NATURAL GAS DECORATIVE PATIO FIRE

INSTALLATION

Continued

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa).

2.Pressurize supply piping system by ei- ther using compressed air or opening main gas valve located on or near gas meter.

3.Check all joints from gas meter to equip- ment shutoff valve (see Figure 5). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Pressure Testing Heater Gas Connections

1.Open equipment shutoff valve (see Figure 4).

2.Open main gas valve located on or near gas meter.

3.Check all joints from equipment shutoff valve to supply hose. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Equipment

Open

Shutoff

 

Valve

 

Closed

Figure 4 - Equipment Shutoff Valve

Gas Meter

Equipment

Shutoff

Valve

SETUP

Your Comfort Glow Patio Fire is designed to operate with lava rock piled in and around the burner, and refractory logs placed on top of the lava rock.

Carefully pour supplied lava rock into basin to cover the burner. Be sure that the burner and burner ports are covered completely by lava rock to better disperse the flame and to create a more natural looking fire.

Manual background CAUTION: Place lava rock carefully. Be careful not to dam- age the burner, ignitor electrode, or thermocouple when adding the lava rock.

Place the six refractory logs on top of the lava rock. The arrangement is left to your personal preference. Try different place- ments to achieve your desired flame pattern.

Note: Sooting on the logs is natural. You may clean with a soft bristle brush.

Manual background WARNING: Allow logs and lava rock to cool completely be- fore handling or rearranging logs.

Manual background WARNING: Solid fuels shall not be burned in this gas fireplace.

BATTERY INSTALLATION

Your Comfort Glow Patio Fire uses an elec- tronic ignitor which requires one AA alka- line battery (not included). The battery com- partment is located in the ignitor module behind the ignitor button.

To install the battery into the ignitor:

1.Locate the ignitor button on the con- trol panel (see Figure 6).

2.Rotate the ignitor button counterclock- wise to remove.

3.Install a fresh AA alkaline battery into the ignitor module, positive terminal first.

4.Replace button by rotating clockwise. Tighten finger tight. Do not over- tighten.

Note: Your fire pit may be lighted using a match (see Lighting Instructions, page 7).

Ignitor Button

Figure 6 - Control Panel

Control Valve Location

Supply Hose

Figure 5 - Checking Gas Joints

For more information, visit www.desatech.com

6

107214

Page 6
Image 6