Installation
WARNING: Make sure the selector switch is in the OFF po- sition before installing heater.
WARNING:Beforeinstallingin a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes andloosepaintbyaqualifiedchim- ney cleaner. Creosote will ignite if highly heated. A dirty chimney fluemaycreateanddistributesoot withinthehouse.Inspectchimney and firebox flue for damage. If damaged, repair flue and firebox before operating heater.
WARNING: Installation, ser- vice and repair of this appliance must be performed by a qualified installer, service agency, compa- ny or gas supplier experienced with this type of gas appliance. Only factory authorized compo- nents listed in these instructions may be used in accordance with manufacturer’s instructions and all codes and requirements of the authority having jurisdiction. Any modifications to this kit, or use of unauthorized compo- nents or accessory items will void manufacturer’s warranty and may result in a hazardous condition.
Installation and Clearances
Figure 2 shows technical information regarding installation of your gas log set. Please make sure all specifications shown are applicable before installation is attempted.
SPECIFICATIONS (W.C.)
| FUEL INLET | MANIFOLD | |
| PRESSURE | PRESSURE | |
| Min. | Max. |
|
|
|
|
|
NG | 7" | 10.5" | 3.5" |
LP | 11" | 14" | 10" |
Figure 2 - Technical Information Chart
Flue Opening Specifications
Note: This vented appliance must be installed only in a
| LOG SIZING REQUIREMENTS |
| ||||
|
| Minimum Firebox Size | Min. | |||
Log |
|
|
| Front | Rear* | Flue |
Size |
| Height | Depth | Width | Width | Size |
18" |
| 17" | 14" | 24" | 20" | 8" |
|
|
|
|
|
|
|
24" |
| 17" | 14" | 28" | 22" | 8" |
|
|
|
|
|
|
|
*Measured at 14" depth.
Figure 3 - Sizes and Clearances
CHECK GAS TYPE
Use the correct gas type (natural or propane/LP) for your unit. If your gas supply is not correct, do not install heater. Call dealer where you bought heater for proper type heater.
WARNING: This appliance is equipped for (natural or pro- pane/LP) gas. Field conversion is not permitted.
venting specifications for installation
The fireplace chimney flue and vent must be draft- ing properly. To check vent for proper drafting: Light a tightly rolled newspaper on one end and place it at the inside front edge of fireplace. Ob- serve smoke and be sure vent is properly drawing it up the chimney. If smoke spills out into the room, extinguish flame and remove any obstruction until proper venting is achieved.
The chimney flue damper must be fixed open to provide a minimum of 43 square inches of free air opening during operation of this log set. A multipurpose damper clamp is provided to fix the damper in position.
www.desatech.com111826-02J