QuickSpecs

HP ProLiant DL160 Generation 5

System Specifications

Power

 

 

ProLiant DL160 G5 Fully Configured

115V/60Hz

220V/50Hz

Fully Loaded System Input Wattage (W)

651

638

Fully Loaded System Input Current (A rms)

5.7

3.0

Fully Loaded System Thermal (BTU- Hr)

2218

2174

Fully Loaded System VA (Volt-Amp)

657

657

System Leakage with all power supplies

1.58

3.03

loaded (mA)

 

 

System Inrush Current with all power

19

37

supplies loaded (A)

 

 

Power cord requirements

Nema 5-15P to IEC320-C13

IEC320-C13 to IEC320-C14

NOTE: Power shown is for a fully configured system consisting of (2) CPU, (8) double-sided DIMMs, (2) HDDs, (1) CD- ROM, and (2) PCI cards.

Power Cord

AF556A

Server Power Cords One 6' Highline (IEC-IEC) power cord ships standard

NOTE: HP ProLiant DL servers no longer ship standard with NEMA power cords (163719-002) that allow connection to 110V US wall outlets in a home or office. ProLiant DL servers are primarily connected to PDU's in data center racks so they now ship standard with only a PDU power cord (416151-B21). If a user wishes to power a ProLiant DL server using a 110V receptacle (NEMA-15), the NEMA power cord (227099-001) must be ordered separately.

If customers require a local power cord, they can check the power cord matrix for the appropriate cord. Please see the following power cord matrix: http://www.hp.com/go/powercordmatrix.

DA - 12902 Worldwide QuickSpecs — Version 19 — 1/26/2009