QuickSpecs

HP ProLiant DL160 Generation 5

Technical Specifications

System Unit

Dimensions (H x W x D) 1.70 x 17.64 x 26.85 in (4.32 x 44.80 x 68.20 cm)

 

(with bezel)

 

 

 

Weight

Maximum

37.00 lb (16.78 kg)

 

(approximate)

(all hard drives, power

 

 

 

supplies, and processors

 

 

 

installed)

 

 

 

Minimum

30.00 lb (13.69 kg)

 

 

(one hard drive, power

 

 

 

supply, and processor

 

 

 

installed)

 

 

Input Requirements

Rated Line Voltage

90 to 140 VAC

 

(per power supply)

 

180 to 264 VAC

 

 

Rated Input Current

7.31A at 115VAC

 

 

 

3.6A at 230VAC

 

 

Rated Input Frequency

47 to 63 Hz

 

 

Rated Input Power

855W (at 100 VAC),

 

 

 

840.72W (at 200 VAC)

 

Power Specifications

To review typical system power ratings use the Power Calculator which

 

 

is available via the online tool located at URL:

 

 

http://h30099.www3.hp.com/configurator/calc/Power%

 

 

20Calculator%20Catalog.xls

 

 

- Click on the system of interest. Example: DL160 G5

 

 

- Follow the instructions of the next screens.

 

Power Supply Output

Rated Steady-State

653.10W (at 100 VAC),

 

(per power supply)

Power

653.08W (at 200 VAC)

 

System Inlet

Operating

50° to 95° F (10° to 35° C) at sea level with an

 

Temperature

 

altitude derating of 1.8°F per every 1000 ft

 

 

 

(1.0°C per every 305 m) above sea level to a

 

 

 

maximum of 10,000 ft (3050 m), no direct

 

 

 

sustained sunlight. Maximum rate of change

 

 

 

is 18°F/hr (10°C/hr). The upper limit may be

 

 

 

limited by the type and number of options

 

 

 

installed.

 

 

 

System performance may be reduced if

 

 

 

operating with a fan fault or above 86°F

 

 

 

(30°C).

 

 

Non-operating

40° to 140° F (-40° to 60° C)

 

 

 

Maximum rate of change is 36°F/hr (20°C/hr).

 

Relative Humidity

Operating

10% to 85% relative humidity (Rh), 82.4°F

 

(non-condensing)

 

(28°C) maximum wet bulb temperature, non-

 

 

 

condensing.

 

 

Non-operating

10% to 95% relative humidity (Rh), 101.7°F

 

 

 

(38.7°C) maximum wet bulb temperature,

 

 

 

non-condensing.

 

Altitude

Operating

10,000 ft (3050 m). This value may be limited

 

 

 

by the type and number of options installed.

 

 

 

Maximum allowable altitude change rate is

 

 

 

1500 ft/min (457 m/min).

DA - 12902 Worldwide QuickSpecs — Version 19 — 1/26/2009