TROUBLE SHOOTING GUIDE

PROBLEM

CAUSE

CORRECTION

 

 

 

Motor will not

Pressure washer not plugged in.

Plug in pressure washer.

 

 

“RESET” button on GFCI not

Push “RESET” button.

start and there

is no humming

pushed.

 

sound

Circuit breaker has tripped or fuse

Reset breaker or replace fuse.

 

is blown.

 

Power

Too much load already on circuit.

Reduce load on circuit.

source circuit

 

Try another 15 amp circuit.

continues to

 

 

 

Using an extension cord.

DO NOT use extension cords.

trip or blow

fuses

 

 

 

 

 

Motor hums but Using an extension cord.

DO NOT use extension cords.

will not start

 

 

 

Supply voltage below required

Check the voltage of the main

 

minimum.

supply line.

 

 

 

No or low

Low water supply.

pressure

 

 

High pressure hose is too long.

Water supply must be at least 5 GPM @ 20 psi.

Use high pressure hose under 100 feet.

Worn nozzle.

Replace nozzle.

Excess noise

Restricted, insufficient water

supply, or air in the water line.

 

 

Water temperature is too high.

Check supply hose, faucet, and inlet screen.

Do not use water from a hot water source, use water only from a cold water faucet.

Pressure

Water leak in high pressure fittings,

fluctuates with-

hose, or gun.

out opening gun

 

Replace hose or gun. If problem continues take to authorized service center.

GFCI switch indi- Circuit breaker has tripped or fuse

Reset breaker or replace fuse. If

cator light does

is blown.

indicator light still does not appear

not appear after

 

have receptacle checked by a

depressed

 

qualified electrician.

 

 

 

GFCI test fails

Circuit breaker has tripped or fuse

Reset breaker or replace fuse. If

 

is blown.

indicator light still does not appear

 

 

have receptacle checked by a

 

 

qualified electrician.

Unit does not

Nozzle clogged

Clean nozzle, if unit still does not

maintain steady

 

maintain steady water pressure,

water pressure

 

turn unit off and contact customer

 

 

service at 1-866-422-4286

Unit continues

Nozzle clogged

Clean nozzle, if unit still does not

to trip GFCI

 

maintain steady water pressure,

switch

 

turn unit off and contact customer

 

 

service at 1-866-422-4286

 

 

 

17- ENG

A17913

Page 17
Image 17
DeVillbiss Air Power Company A17913, VR1600E important safety instructions Trouble Shooting Guide, Problem Cause Correction