PROBLEM | POSSIBLE CAUSE | CORRECTION | |
|
|
| |
Water or oil leaking | A small amount of leakage is | If excessive leaking occurs call | |
from bottom of pump | normal | Customer Service Department | |
|
|
| |
Pressure increases | Bypass valve not operating | Call Customer Service Department | |
when gun is closed | properly |
| |
|
|
| |
Motor running but | Faucet closed | Open faucet | |
pump not building | Unit has been stored in freezing | Thaw out unit completely including | |
maximum pressure or | |||
temperatures | hose, gun, and wand | ||
has irregular pressure | |||
Water inlet screen clogged | Clean screen. See section 5.4 | ||
| |||
| Air in pump | Let pressure washer run with gun | |
|
| open and wand removed until | |
|
| steady stream of water is released. | |
| Adjustable pressure knob not | Set to maximum position. See | |
| set to maximum position | Section 4.2 | |
| Suction or discharge valves | Call Customer Service Department | |
| clogged or worn out |
| |
| Call Customer Service Department | ||
| effectively |
| |
|
|
| |
No intake of chemicals | Injection tube not securely | Push firmly into machine | |
| inserted into pressure washer |
| |
| Tube cracked or split | Replace tubing | |
| Wrong Nozzle setting | Switch nozzle to low pressure | |
| Nozzle Blocked | Clean Nozzle. See Section 5.2 | |
| Injection tube strainer clogged | Clean strainer | |
| Dried chemicals in injector | Dissolve by running warm water | |
|
| through the injection tube | |
|
|
| |
Trigger will not move | Gun safety lock engaged | Release safety lock | |
|
|
|
17- ENG | D28921 |