Never turn water supply off while pressure washer engine is running or damage to pump will result.

• DO NOT stop spraying water for more than two

 

minutes at a time. Pump operates in bypass

 

mode when spray gun trigger is not pressed.

 

When the temperature inside the pump rises

 

too high the thermal relief valve (T) will open

 

and release a gush of water in an effort to lower

T

the temperature inside the pump. The thermal

 

relief valve will then close. If pump is left in bypass mode for more than two minutes internal components of the pump can be damaged.

Start-up Procedure

1.In a well-ventilated outdoor area, add fresh, high-quality, unleaded gasoline with a pump octane rating of 86 or higher. Do not overfill. Wipe up spilled fuel before starting the engine. Refer to engine instruction manual for correct procedure.

2.Check engine oil level. Refer to the engine instruction manual for correct procedure.

3.Connect the water hose to the water source. Turn the water source on to remove all air from the hose. When a steady stream of water is present, turn the water source off.

4.Verify the filter screen (U) is in water inlet of

pump. The cone side faces out.

5. Connect the cold water source (V) to pump inlet.

NOTE: Water source must provide a minimum

 

of 5 gallons per minute at 20 pSI.

U

Warning: To reduce the possibility of con-

 

tamination always protect against backflow when connected to a potable water system.

6.

Connect high-pressure hose (C) to pump

c

 

outlet.

7.

If applying a chemical or cleaning solution,

 

 

refer to Chemicals and Cleaning

 

 

Solvents.

 

8.

Turn the water source on.

 

Caution: Risk of property damage. Failure

V

to do so could cause damage to the pump.

 

9.Remove all air from the pump and high pressure hose by depress- ing trigger until a steady stream of water is present.

10.Start engine. Refer to the engine instruction manual for correct procedure.

Warning: Risk of unsafe operation. If engine does not start after two pulls, squeeze trigger of gun to relieve pump pressure. Pull starter cord slowly until resistance is felt. Then pull cord rapidly to avoid kickback and prevent hand or arm injury.

11. Depress trigger on gun to start water flow.

Warning: Risk of unsafe operation. Stand on a stable surface and grip gun/wand firmly with both hands. Expect the gun to kickback when triggered.

12. Release trigger to stop water flow.

DANGER: Risk of injury from spray. Engage the

W

trigger lock (W) when gun is not in use to prevent

 

accidental spraying.

 

13. Adjust spray for the task being performed by changing quick connect nozzle. Refer to Spray Wand Nozzles.

Shutting Down

1.If chemicals were applied, place the chemical hose into a container of clean water and draw clean water through chemical injection system to rinse system thoroughly.