Code

possible cause

POSSIBLE SOLUTION

 

 

 

15

Extension cord is wrong length or gauge

Check for proper gauge wire and cord length. See

 

 

Extension Cords under Installation.

 

 

 

16

Loose electrical connections

Contact a DeWALT factory service center or a DeWALT

 

 

authorized service center.

 

 

 

17

Possible defective motor.

Contact a DeWALT factory service center or a DeWALT

 

 

authorized service center.

 

 

 

 

18

Fuse blown, circuit breaker tripped

1.

Check fuse box for blown fuse and replace as necessary.

 

 

 

Reset circuit breaker. Do not use a fuse or circuit

 

 

 

breaker with higher rating than that specified for your

 

 

 

particular branch circuit.

 

 

2.

Check for proper fuse. Use only a time delay fuse.

 

 

3.

Check for low voltage conditions and/or proper extension

 

 

 

cord.

 

 

4.

Disconnect the other electrical appliances from circuit or

 

 

 

operate the compressor on its own branch circuit.

 

 

 

19

Tank pressure exceeds pressure switch cut-inpressure

Motor will start automatically when tank pressure drops

 

 

below cut-inpressure of pressure switch.

 

 

 

 