•Circuit is not used to supply any other electrical needs.
•Extension cords comply with specifications.
•Circuit is equipped with a 15 amp circuit breaker or 15 amp time delay fuse. NOTE: If compressor is connected to a circuit protected by fuses, use only time delay fuses. Time delay fuses should be marked “D” in Canada and “T” in the US.
If any of the above conditions cannot be met, or if operation of the compressor repeatedly causes interruption of the power, it may be necessary to operate it from a 20 amp circuit. It is not necessary to change the cord set.
Location
•Locate the air compressor in a clean, dry and well ventilated area.
•The air compressor should be located at least 12" (30.5 cm) away from the wall or other obstructions that will interfere with the flow of air.
•The air compressor pump and shroud are designed to allow for proper cooling. The ventilation openings on the compressor are necessary to maintain proper operating temperature. Do not place rags or other containers on or near these openings.
OPERATION
How to Use Your Unit (Fig. 1)
HOW TO STOP
1.Set the On/Off switch (A) to OFF.
2.Unplug unit when not in use.
BEFORE STARTING
WARNING: Do not operate this unit until you read this instruction manual for safety, operation and maintenance instructions.
BEFORE EACH START-UP
1. Set the On/Off switch (A) to OFF.
11
2.Plug the power cord into the correct branch circuit receptacle. (Refer to Voltage and Circuit Protection paragraph in the Installation section of this manual.)
3.Turn the regulator knob (D) counterclockwise to set the outlet pressure to zero.
4.Attach hose and accessories.
WARNING: Risk of unsafe operation. Firmly grasp air hose in hand when installing or disconnecting to prevent hose whip.
WARNING: Risk of unsafe operation. Do not use damaged or worn accessories.
NOTE: The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick connect body (E).
WARNING: Risk of Bursting. Too much air pressure causes a hazardous risk of bursting. Check the manufacturer’s maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating.
NOTICE: Risk of property damage. Compressed air from the unit may contain water condensation and oil mist. Do not spray unfiltered air at an item that could be damaged by moisture. Some air tools and accessories may require filtered air. Read the instructions for the air tools and accessories.
HOW TO START
1.Set the On/Off switch (A) to ON and allow tank pressure to build. Motor will stop when tank pressure reaches
2.Turn regulator knob (D) clockwise to increase pressure and stop when desired pressure is reached.
WARNING: Risk of unsafe operation. If any unusual noise or vibration is noticed, stop the compressor immediately and have it checked by a trained service technician.
The compressor is ready for use.