MAINTENANCE | To Drain Tank (Fig. 1) |
Customer Responsibilities
English | Drain Tank | Before | Daily or | See tank |
each use | X | warning | ||
|
| after each | ||
|
|
| use | label |
| Check Safety Valve | X |
|
|
|
|
|
|
|
| Remove tank from service |
|
| X1 |
| 1- For more information, call | WALT |
WARNING:Riskofunsafeoperation.Unitcyclesautomatically when power is on. When performing maintenance, you may be exposed to voltage sources, compressed air, or moving parts. Personal injuries can occur. Before performing any maintenance or repair, disconnect power source from the compressor and bleed off all air pressure.
NOTE: See Operation section for the location of controls.
To Check Safety Valve (Fig. 1)
WARNING: Risk of Bursting. If the safety valve does not work properly,
WARNING: Risk from Flying Objects. Always wear certified safety equipment: ANSI Z87.1 eye protection (CAN/CSA Z94.3) with side shields.
Before starting compressor, pull the ring on the safety valve (F) to make sure that the safety valve operates freely. If the valve is stuck or does not operate smoothly, it must be replaced with the same type of valve.
12
WARNING: Risk of Unsafe Operation. Air tanks contain high pressure air. Keep face and other body parts away from outlet of drain. Use ANSI Z87.1 eye protection (CAN/CSA Z94.3) when draining as debris can be kicked up into face.
WARNING: Risk from noise. Always wear proper hearing protection during use. Under some conditions and duration of use, noise from this product may contribute to hearing loss.
NOTE: All compressed air systems generate condensate that accumulates in any drain point (e.g., tanks, filter, aftercoolers, dryers). This condensate contains lubricating oil and/or substances which may be regulated and must be disposed of in accordance with local, state, and federal laws and regulations.
WARNING: Risk of Bursting. Water will condense in the air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture.
NOTICE: Risk of Property Damage. Drain water from air tank may contain oil and rust which can cause stains.
1.Set the On/Off switch (A) to OFF.
2.Turn the regulator knob (D) counterclockwise to set the outlet pressure to zero.
3.Remove the air tool or accessory.
4.Place a suitable container under the drain valve to catch discharge.
5.Pull ring on safety valve (F) allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring.
6.Drain water from air tank by opening drain valve (G) on bottom of tank.
7.After the water has been drained, close the drain valve. The air compressor can now be stored.