Issues Sorted by Type, Dialogic® Multimedia Platform (Continued)

Issue Type

Defect No.

SU

Product or

Description

No.

Component

 

 

 

 

 

 

 

 

Known

IPY00038149

 

hardware

Shut down is not supported by opening of the Dialogic®

 

 

 

 

Multimedia Blade latch. The blue LED (hotswap LED)

 

 

 

 

on the blade will blink indefinitely but never turn solid to

 

 

 

 

indicate shut down complete.

 

 

 

 

Workaround: To shut down the blade, log on locally

 

 

 

 

through the serial port or connect over the network and

 

 

 

 

initiate a shutdown. The blade can be initialized by

 

 

 

 

removing and reseating in the chassis.

 

 

 

 

 

Known

IPY00038148

 

hardware

Activation and de-activation via the shelf manager is not

 

 

 

 

supported on the Dialogic® Multimedia Blade latch. The

 

 

 

 

blue LED (hotswap LED) on the blade will blink

 

 

 

 

indefinitely but never turn solid to indicate shut down

 

 

 

 

complete.

 

 

 

 

Workaround: To shut down the blade, log on locally

 

 

 

 

through the serial port or connect over the network and

 

 

 

 

initiate a shutdown. The blade can be initialized by

 

 

 

 

removing and reseating in the chassis.

 

 

 

 

 

Known

IPY00038147

 

hardware

If the Dialogic® Multimedia Blade is deactivated using

 

 

 

 

the shelf manager, the kernel panics while shutting

 

 

 

 

down the system services and does not complete the

 

 

 

 

hot swap extraction cycle.

 

 

 

 

The craftsperson can then remove and/or restart the

 

 

 

 

blade.

 

 

 

 

 

Known

IPY00036028

 

hardware

The PSTN Rear Transition Module (RTM) generates

 

 

 

 

major events to the shelf manager stating that the

 

 

 

 

sensor “RTM +1.0 V” went over the upper critical limit.

 

 

 

 

 

Known

IPY00036026

 

hardware

The Dialogic® Multimedia Blade generates major

 

 

 

 

events to the shelf manager stating that the sensor

 

 

 

 

“SBC +1.1V SUS” went over the upper critical limit.

 

 

 

 

 

Known

IPY00032623

 

MSML

‘audiosamplerate’ and ‘audiosamplesize’ must be

 

 

 

 

specified by the MSML application server when playing

 

 

 

 

a .WAV file from an offset.

 

 

 

 

 

Known

IPY00034143

 

PSTN call control

When using all 496 time slots on 16 E1 trunks, there is

 

 

 

 

a 1% failure rate with DTMF digit detection.

 

 

 

 

 

Known

IPY00034168

 

CLI

On a CLI shutdown (by dlstop), the CLI session port is

(permanent)

 

 

 

not immediately released. If a user does a dlstop

 

 

 

 

followed by a dlstart too quickly (within 20 seconds), the

 

 

 

 

dlstart may not be able to start the CLI session.

 

 

 

 

Workaround: If the CLI agent start part of dlstart fails,

 

 

 

 

then the workaround is to do the following from a

 

 

 

 

terminal window after around 20 seconds:

 

 

 

 

dlservices cli start

 

 

 

 

If it doesn't work immediately, try again in a few

 

 

 

 

seconds. This will start the CLI agent and user will be

 

 

 

 

able to use telnet again.

 

 

 

 

 

14Dialogic® Multimedia Software for ATCA Release 1.0 Release Update, Rev 06 — January 23, 2008 Dialogic Corporation

Page 14
Image 14
Dialogic 05-2548-006, DIALOGIC MULTIMEDIA SOFTWARE FOR ADVANCEDTCA RELEASE 1.0 manual Dlservices cli start, Msml