Issues Sorted by Type, Dialogic® Multimedia Platform (Continued)

Issue Type

Defect No.

SU

Product or

Description

No.

Component

 

 

 

 

 

 

 

 

Resolved

IPY00035425

77

PSTN call control

The firmware is printing unnecessary logs to the

 

 

 

 

messages file. These messages can be ignored.

 

 

 

 

The messages are similar to the following:

 

 

 

 

Oct 19 11:10:31 py1atcatvl16 CLIAGENT: From

 

 

 

 

Component: IPMS_ShowLinkAlarm : @

 

 

 

 

LastChange:0 seconds @

 

 

 

 

Oct 19 11:13:22 py1atcatvl16 ssp_x86Linux_boot: line

 

 

 

 

3056, file src/c/tsccomp.c

 

 

 

 

Oct 19 11:13:22 py1atcatvl16 ssp_x86Linux_boot: line

 

 

 

 

1198, file src/c/tsccomp.c

 

 

 

 

Oct 19 11:13:22 py1atcatvl16 ssp_x86Linux_boot: line

 

 

 

 

3056, file src/c/tsccomp.c

 

 

 

 

Oct 19 11:13:22 py1atcatvl16 ssp_x86Linux_boot: line

 

 

 

 

1198, file src/c/tsccomp.c

 

 

 

 

Oct 19 11:13:22 py1atcatvl16 [0xffff0000]TSC.000

 

 

 

 

Received unexpected message Unknown message

 

 

 

 

type(0x1244) from 0:0:2:b [0xffff0000]TSC.001

 

 

 

 

Received unexpected message Unknown message

 

 

 

 

type(0x1234) from 0:0:2:b [0xffff0000]TSC.000

 

 

 

 

Received unexpected message Unknown message

 

 

 

 

type(0x1244) from 0:0:2:b [0xffff0000]TSC.032

 

 

 

 

Received unexpected message Unknown message

 

 

 

 

type(0x1234) from 0:0:2:b

 

 

 

 

Oct 19 11:14:47 py1atcatvl16 ssp_x86Linux_boot:

 

 

 

 

RtcWriteBEvtDetected error: Event type -4605 is out of

 

 

 

 

range (max=127)

 

 

 

 

 

Resolved

IPY00034277

--

TDM bus

Receive failures in the DS1 adapter when attempting to

 

 

 

 

add a clock source to the FallBackList table via SNMP.

 

 

 

 

The Clock FallBack List is not functional; the user can

 

 

 

 

choose a clock but will not be able to rely on a fallback

 

 

 

 

list.

 

 

 

 

 

Resolved

IPY00034275

--

TDM bus

When no fallback list is present, the TDM clock

 

 

 

 

manager in the firmware will attempt to access the non-

 

 

 

 

existent list when the cable is unplugged from a PSTN

 

 

 

 

trunk. This causes two identical events to be forwarded

 

 

 

 

to the CLI and SNMP saying that the TDM clock has

 

 

 

 

changed sources twice. This is misleading because in

 

 

 

 

actuality the clock source has not changed and red

 

 

 

 

alarms on a particular trunk (or trunks) should not have

 

 

 

 

any effect on the default internal oscillator clock source.

 

 

 

 

The Clock FallBack List is not functional; the user can

 

 

 

 

choose a clock but will not be able to rely on a fallback

 

 

 

 

list.

 

 

 

 

 

Resolved

IPY00033580

--

third party support

Using RFC2833 with coder type G723.1 63(56)K,

 

 

 

 

30ms, 1(2) fpp, VAD off, digits are missed at a rate of 1

 

 

 

 

to 2%. (An example of missing digits is received

 

 

 

 

“19d6a*”, expected “159d86a*”.)

 

 

 

 

 

Dialogic® Multimedia Software for ATCA Release 1.0 Release Update, Rev 06 — January 23, 2008

17

Dialogic Corporation

 

Page 17
Image 17
Dialogic DIALOGIC MULTIMEDIA SOFTWARE FOR ADVANCEDTCA RELEASE 1.0 Existent list when the cable is unplugged from a Pstn