Dialogic® PBX Integration Board User’s Guide
Table 35. DTerm III Series LCD Indicator States (Upper Nibble)
Binary Hex Description
0000 0000 0x00 Off
0000 0001 0x01 Flutter (red)
0000 0010 0x02 Wink (red)
0000 0011 0x03 Rapid wink (red)
0000 0100 0x04 Interrupted rapid wink (red)
0000 0101 0x05 Interrupted wink (red)
0000 0110 0x06 Interrupted unlit (red)
0000 0111 0x07 Steady on (red)
0000 1001 0x09 Flutter (green)
0000 1010 0x0A Wink (green)
0000 1011 0x0B Rapid wink (green)
0000 1100 0x0C Interrupted rapid wink (green)
0000 1101 0x0D Interrupted wink (green)
0000 1110 0x0E Interrupted unlit (green)
0000 1111 0x0F Steady on (green)
Reading LCD Indicators on Flexible Line Keys
The Dialogic® PBX Integration Board can determine the state of its LCD
indicators by using the d42_indicators( ) function to retrieve the LCD
indicators data. This function places the Line Indicator data (16 bytes) in an
application buffer. Bytes 00-15 contain the indicator status for Feature Keys
00-15, respectively (see Table 36).
154