Dialogic SI/240 user service Warranty and Return Information, Install the Board, Sales Assistance

Models: SI/240

1 2
Download 2 pages 45.58 Kb
Page 2
Image 2
Dialogic® Station Interface Box

Dialogic® Station Interface Box

 

 

 

 

 

 

 

 

 

 

 

Top Mounting

 

 

 

 

 

 

 

 

 

Screws (4 Req'd)

 

 

 

 

 

 

 

SI\240 Board

 

 

 

 

 

 

 

 

 

 

(Installed)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Base Board

 

 

 

 

 

 

 

 

 

 

Connector

 

STA

49-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72

 

 

 

 

 

SI\240

P4

 

 

 

 

 

 

 

 

 

STA

 

 

 

 

 

 

Connector

 

1-

 

 

 

 

Daughter

 

Power Supply

 

 

 

 

 

 

Board

P5

 

24

STA

 

 

 

 

Connector

 

 

73-

 

Remove

 

Connector

 

STA

 

 

CoverPlate

 

 

 

 

 

96

 

 

Connector

 

S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TA

25-

 

 

 

 

 

 

 

 

 

 

48

 

STA

 

 

 

Board

 

 

 

 

 

 

97-

 

 

 

 

 

 

 

 

 

Mounting

 

Rear Mounting

 

DIA

G

 

 

120

 

 

 

 

Posts

 

 

 

 

 

 

 

Screws (2 Req'd)

 

 

 

J

 

 

 

 

 

 

 

 

 

 

1

J2

J3

 

 

 

 

 

 

 

 

 

J4

 

 

 

 

 

Diag

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Port

 

 

 

 

 

 

 

 

 

 

8-Pin

 

 

 

 

 

 

 

 

 

Modular Jacks

 

 

 

Base

 

 

 

 

 

 

 

 

 

 

Board

4.Guide the SI/240 board’s STA connector into the hole on the SIB rear panel, carefully lining up the top mounting holes with the base board mounting posts.

5.Secure the board with four top mounting screws (supplied) and the two saved rear mounting screws.

5. Warranty and Return Information Note: Make sure that the SI/240 board STA connector contacts the SIB rear panel. Start the four top mounting screws by hand first; then install and fully tighten the two rear mounting screws. Finally, fully tighten the top mounting screws.

6.After installing and connecting the SI/240 board(s), replace the SIB cover and connect the power cord.

5. Warranty and Return Information

Warranty Period

For specific warranty information for this board, refer to the Warranty section of the Products page, located at this URL: http://www.dialogic.com/warranties/.

Contacting Technical Support

Dialogic provides technical support for its products through a network of value added distributors who are trained to answer technical questions on installing and configuring Dialogic® products. If you are unsure how to contact your support channel, please call Dialogic in the United States at 973-967-6600 (9am-5pm EST) and we will assist in obtaining the appropriate support channel.

Outside the United States please refer to http://www.dialogic.com/support/contact to obtain local contact information.

Dialogic also provides direct support via Dialogic® Pro™ Services agreements. For more details of direct support from Dialogic please refer to: http://www.dialogic.com/support/DialogicPro.

Returning a Product

To return a board for warranty repair or any other returns, please refer to the following: http://www.dialogic.com/support/hwfaults.

To return a board for warranty repair, please refer to the

for your area. Address, telephone and fax numbers, are available at the Dialogic website located at: http://www.dialogic.com/contact.htm.

To purchase Dialogic® products, please refer to the following website to locate the appropriate supplier. http://www.dialogic.com/purchase.htm.

All contents of this document are furnished for informational use only and are subject to change without notice and do not represent a commitment on the part of Dialogic Corporation or its subsidiaries (“Dialogic”). Reasonable effort is made to ensure the accuracy of the information contained in the document. However, Dialogic does not warrant the accuracy of this information and cannot accept responsibility for errors, inaccuracies or omissions that may be contained in this document.

INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH DIALOGIC® PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN A SIGNED AGREEMENT BETWEEN YOU AND DIALOGIC, DIALOGIC ASSUMES NO LIABILITY WHATSOEVER, AND DIALOGIC DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF DIALOGIC PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT OF A THIRD PARTY.

Dialogic products are not intended for use in medical, life saving, life sustaining, critical control or safety systems, or in nuclear facility applications.

It is possible that the use or implementation of any one of the concepts, applications, or ideas described in this document, in marketing collateral produced by or on web pages maintained by Dialogic may infringe one or more patents or other intellectual property rights owned by third parties. Dialogic does not provide any intellectual property licenses with the sale of Dialogic products other than a license to use such product in accordance with intellectual property owned or validly licensed by Dialogic and no such licenses are provided except pursuant to a signed agreement with Dialogic. More detailed information about such intellectual property is available from Dialogic’s legal department at 9800 Cavendish Blvd., 5th Floor, Montreal, Quebec, Canada H4M 2V9. Dialogic encourages all users of its products to procure all necessary intellectual property licenses required to implement any concepts or applications and does not condone or encourage any intellectual property infringement and disclaims any responsibility related thereto. These intellectual property licenses may differ from country to country and it is the responsibility of those who develop the concepts or applications to be aware of and comply with different national license requirements.

Dialogic, Diva, Eicon, Eicon Networks, Eiconcard, Dialogic Pro and SIPcontrol, among others, are either registered trademarks or trademarks of Dialogic. Dialogic's trademarks may be used publicly only with permission from Dialogic. Such permission may only be granted by Dialogic’s legal department at 9800 Cavendish Blvd., 5th Floor, Montreal, Quebec, Canada H4M 2V9. Any authorized use of Dialogic's trademarks will be subject to full

4.Install the Board

1.Working at a static-safeguarded work area, disconnect the SIB’s power cord from the electrical outlet and remove the SIB cover.

Warranty Period Note: To remove the SIB cover, you must first remove the top three screws on the front panel.

2.Remove the desired STA XX-XXXconnector access cover plate and save the two rear mounting screws.

3.Attach the SI/240 board ribbon cable to the appropriate base board connector (P3, P4, or P5).

Contacting Technical Support Note: When you fully seat the SI/240 ribbon cable connector, the base board ribbon cable extractor clips lock into the vertical position.

following: http://www.dialogic.com/support/hwfaults. For all other returns, contact your vendor or Dialogic Customer Support (for more information, see http://www.dialogic.com/support/contact/ ).

6. Sales Assistance

If you have a sales question, please contact your

local Sales Representative or the Regional Sales Office

respect of the trademark guidelines published by Dialogic from time to time and any use of Dialogic’s trademarks requires proper acknowledgement. The names of actual companies and products mentioned herein are the trademarks of their respective owners.

Page 2
Image 2
Dialogic SI/240 Warranty and Return Information, Install the Board, Sales Assistance, Dialogic Station Interface Box