Installation Instructions (cont'd)
Facts to Consider About the | Facts to Consider | About The |
Location | Convertible Lower | Element |
You should carefully choose an indoor location for the new water heater, because the placement is a very important consid- eration for the safety of the occupants in the building and for the most economical use of the appliance. This water heater is not intended for outdoor installation.
Whether replacing an old water heater or putting the water heater in a new location, the following critical points must be observed.
•The location selected should be indoors as close to and as centralized with the water piping system as possible. This water heater, as well as all water heaters, will eventually leak. Do not install without adequate drainage provisions where water flow will cause damage.
-_ CAUTION
WATER HEATERS EVENTUALLY LEAK: Installation of the water heater must be accomplishedin sucha manner that if the tank or any connectionsshouldleak, the flow of water will not cause damage to the structure. For this reason, it is not advisableto install the water heater in an attic or upper floor. When such locationscannot be avoid- ed, a suitable drain pan should be installed under the water heater. Drain pans are available at your local Sears
stores. Such a drain pan must be piped to an adequate drain. Under no circumstances is the manufacturer or
Sears to be held liable for any water damage in connec- tion with this water heater.
The Upper Element (if a double element model), is a conven- tional 3800 watt element which only operates at its rated wattage on 240 volts. (See rating plate on water heater).
The Lower Element of the water heater can be converted from operation at 3800 watts to 5500 watts on a 240 volt system.
Read and follow water heater warnings and instructions. If after reading these instructions in this manual, if you do not under- stand any portion, call Sears Service Center.
iI WARNING
Before making the conversion to 5500 watts, check the
(I)power supply...must be 240 volts, (2) wiring...10 gauge AWG, Type TW, 60°C or equivalent, and (3) Circuit breakers or fusing...capable of 30 amp loading. Also, the installation must conform with this manual, local codes and electric utility rules. Failure to comply can result in
DEATH. SERIOUS BODILY INJURY. OR PROPERTY
DAMAGE.
150
CAUTION
INSTALLATION IN RESIDENTIAL GARAGES. The water heater must be located and/or protected so it is not subjectto physicaldamage by a mov ng veh cle.
•The location selection must provide adequate clearances for servicing and proper operation of the water heater.
NOTE: Whether or not the element conversion is made the
model rating plate must be marked. Using a hard point ink pen, check the appropriate block within the model rating plate, which is located adjacent to the lower access panel.