Installation Instructions (cont'd)
2. The convertible element is located behind the lower access
panel of the water heater. Remove the two screws securing the access panel, and remove panel.
5.Lower Element: LiE out the tab as shown to unclip the ter- minal cover from the thermostat. The terminal cover can now
be removed from the thermostat.
Lift out tab to until!
ternllnaJ cover from
,AC
t_ermosta_ | TERMINAL | COVER | PLASTIC | TABS ON | |
CLIPPED | TO THER- | ||||
'BOTH SIDES OF | |||||
| |||||
|
|
| |||
| P"O%?TATTH's | TERMINAL | COVER | ||
| HOLD IT | IN | |||
|
|
|
PLACE.
THERMOSTAT
BRACKET
3.Remove the adjustment dial from the thermostat by gently pulling it directly away from the thermostat.
_LEMENT
4. Remove the insulation block to expose the opening.
6.Remove the screws from terminal 2 of the element, and move the looped end of the wire aside.
7.The buss bar is labeled 5500 W. Place the buss bar over terminals 2 and 3 with the 5500 W visible. Install the extra screw provided into terminal 3.
8.The wire removed from terminal 2 has a looped end. It must remain looped and now be placed (as shown) on top of the buss bar, over the opening of terminal 2, and secured using the remaining screw.