CAUTION

Bind the auxiliary pipes (two) and connecting cable with facing tape tightly.

In case of leftward piping and rear-leftward piping, bind the auxiliary pipes (two) only with facing tape.

Indoor unit

10-3-7. Drainage

1. Run the drain hose at a downward sloped angle.

NOTE :

Hole should be made at a slight downward slant on the outdoor side.

Do not rise the drain hose.

Do not form the drain hose

 

into the waved shape.

Auxiliary pipes

Installation plate

Connecting cable

50mm or more

Fig. 10-3-18

Carefully arrange the pipes so that none of the pipes stick out of the rear plate of the indoor unit.

Carefully connect the auxiliary pipes and connecting pipes to each other and cut off the insulating tape wound on the connecting pipe to avoid double-taping at the joint, moreover, seal the joint with the vinyl tape, etc.

Since condensation can result in machine performance trouble, be sure to insulate both connecting pipes. (Use polyethylene foam as insulating material.)

When bending a pipe, be careful not to crush it.

10-3-6. Indoor Unit Installation

1.Pass the pipe through the hole in the wall, and hook the indoor unit on the installation plate at the upper hooks.

2.Swing the indoor unit to right and left to confirm that it is firmly hooked on the installation plate.

3.While pressing the indoor unit onto the wall, hook it at the lower part on the installation plate.

Pull the indoor unit toward you to confirm that it is firmly hooked on the installation plate.

1 Hook here

1 Installation plate

2

 

Hook

Push (unhook)

 

Fig. 10-3-19

For detaching the indoor unit from the installation plate pull the indoor unit toward you while pushing the bottom up at the specified places.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Do not put the

Do not put the drain

drain hose end

hose end in the

into water.

drainage ditch.

Fig. 10-3-21

2.Put water in the drain pan and make sure that the water is being drained outside.

3.When connecting extension drain hose, insulate the connection part of extension drain hose with shield pipe.

Shield pipe

Drain hose Inside the room

 

 

 

Extension drain hose

 

 

Fig. 10-3-22

CAUTION

Install the drain pipe for proper drainage.

Improper drainage can result in water dripping inside the room.

This air conditioner has been designed to drain water collected from condensation which forms on the back of the indoor unit, to the drain pan.

Therefore, do not locate the power cord and other parts at a high place than the drain guide.

Wall

Drain guide

Space for pipes

Push

Push

Fig. 10-3-20

Fig. 10-3-23

– 54 –

Page 54
Image 54
Toshiba RAS-B16GKVP-E, RAS-B13GKVP-E, RAS-B10GKVP-E, RAS-13GAVP-E, RAS-16GAVP-E Drainage, Indoor Unit Installation

RAS-10GAVP-E, RAS-16GAVP-E, RAS-13GAVP-E, RAS-B10GKVP-E, RAS-B13GKVP-E specifications

Toshiba has long been a renowned name in the world of air conditioning, delivering reliable and energy-efficient solutions that meet the demands of modern living. Among their innovative product line, the Toshiba RAS-B13GKVP-E, RAS-10GAVP-E, RAS-B10GKVP-E, RAS-16GKVP-E, and RAS-13GAVP-E stand out for their advanced features and cutting-edge technologies.

The RAS-B13GKVP-E is a powerful air conditioning unit designed for medium-sized rooms. It boasts a robust cooling capacity, ensuring comfort even during the hottest days. One of its standout features is the inverter technology, which optimizes energy consumption by adjusting the compressor speed according to the temperature, resulting in significant energy savings.

Next, the RAS-10GAVP-E is tailored for smaller spaces, offering efficient cooling and heating capabilities. It comes with an easy-to-use remote control and a user-friendly interface, allowing for effortless operation. The model also incorporates a quiet operation feature, making it suitable for bedrooms and study areas where noise can be a distraction.

The RAS-B10GKVP-E strikes a balance between size and efficiency, ideal for compact living spaces. Its dual cooling and heating function ensures year-round climate control. This model further enhances indoor air quality with its built-in filters, which capture dust and allergens, creating a healthier environment for occupants.

For larger areas, the RAS-16GKVP-E provides an impressive cooling capacity combined with turbo mode functionality. This feature enables rapid cooling of spaces during sweltering summer days. Its sleek design and compact form factor allow for easy installation, making this unit a popular choice for both residential and commercial applications.

Lastly, the RAS-13GAVP-E excels in energy efficiency with its eco-friendly refrigerant options. It is equipped with a smart control system that allows users to monitor and adjust settings remotely, adding convenience and flexibility to its operation. This model is particularly beneficial for users looking to minimize their carbon footprint while enjoying the comfort of climate control.

Overall, Toshiba's lineup of air conditioning units, including RAS-B13GKVP-E, RAS-10GAVP-E, RAS-B10GKVP-E, RAS-16GKVP-E, and RAS-13GAVP-E, promises high performance, energy efficiency, and advanced technology. These features affirm Toshiba's commitment to creating a comfortable indoor environment while ensuring sustainability and user satisfaction.