11-1. First Confirmation

11-1-1. Confirmation of Power Supply

Confirm that the power breaker operates (ON) normally.

11-1-2. Confirmation of Power Voltage

Confirm that power voltage is AC 220–230–240 ± 10%.

If power voltage is not in this range, the unit may not operate normally.

11-1-3. Operation Which is not a Trouble (Program Operation)

For controlling the air conditioner, the program operations are built in the microcomputer as described in the following table.

If a claim is made for running operation, check whether or not it meets to the contents in the following table.

When it does, we inform you that it is not trouble of equipment, but it is indispensable for controlling and main- taining of air conditioner.

 

Table 11-1-1

 

 

 

No.

Operation of air conditioner

Description

 

 

 

1

When power breaker is turned “ON”, the

The OPERATION lamp of the indoor unit flashes when

 

operation indicator (Green) of the indoor

power source is turned on. If [START/STOP] button is

 

unit flashes.

operated once, flashing stops.

 

 

(Flashes also in power failure)

 

 

 

2

Compressor may not operate even if the

The compressor does not operate while compressor

 

room temperature is within range of

restart delay timer (3-minutes timer) operates.

 

compressor-ON.

The same phenomenon is found after power source has

 

 

been turned on because 3-minutes timer operates.

 

 

 

3

In Dry and ECO mode, FAN (air flow)

The air flow indication is fixed to [AUTO].

 

display does not change even though FAN

 

 

(air flow select) button is operated.

 

 

 

 

4

Increasing of compressor motor speed

For smooth operation of the compressor, the compres-

 

stops approx. 30 seconds after operation

sor motor speed is restricted to Max. 41 rps for 2 min-

 

started, and then compressor motor speed

utes, and Max.91 rps for 2 minutes to 3 minutes, respec-

 

increases again approx. 30 seconds after.

tively after the operation has started.

 

 

 

5

In AUTO mode, the operation mode is

After selecting Cool or Heat mode, select an operation

 

changed.

mode again if the compressor keeps stop status for 15

 

 

minutes.

 

 

 

6

In HEAT mode, the compressor motor

The compressor motor speed may decrease by high-

 

speed does not increase up to the maxi-

temp. release control (Release protective operation by

 

mum speed or decreases before the

temp.-up of the indoor heat exchanger) or current

 

temperature arrives at the set temperature.

release control.

 

 

 

– 62 –

Page 62
Image 62
Toshiba RAS-B10GKVP-E, RAS-B16GKVP-E First Confirmation, Confirmation of Power Supply, Confirmation of Power Voltage

RAS-10GAVP-E, RAS-16GAVP-E, RAS-13GAVP-E, RAS-B10GKVP-E, RAS-B13GKVP-E specifications

Toshiba has long been a renowned name in the world of air conditioning, delivering reliable and energy-efficient solutions that meet the demands of modern living. Among their innovative product line, the Toshiba RAS-B13GKVP-E, RAS-10GAVP-E, RAS-B10GKVP-E, RAS-16GKVP-E, and RAS-13GAVP-E stand out for their advanced features and cutting-edge technologies.

The RAS-B13GKVP-E is a powerful air conditioning unit designed for medium-sized rooms. It boasts a robust cooling capacity, ensuring comfort even during the hottest days. One of its standout features is the inverter technology, which optimizes energy consumption by adjusting the compressor speed according to the temperature, resulting in significant energy savings.

Next, the RAS-10GAVP-E is tailored for smaller spaces, offering efficient cooling and heating capabilities. It comes with an easy-to-use remote control and a user-friendly interface, allowing for effortless operation. The model also incorporates a quiet operation feature, making it suitable for bedrooms and study areas where noise can be a distraction.

The RAS-B10GKVP-E strikes a balance between size and efficiency, ideal for compact living spaces. Its dual cooling and heating function ensures year-round climate control. This model further enhances indoor air quality with its built-in filters, which capture dust and allergens, creating a healthier environment for occupants.

For larger areas, the RAS-16GKVP-E provides an impressive cooling capacity combined with turbo mode functionality. This feature enables rapid cooling of spaces during sweltering summer days. Its sleek design and compact form factor allow for easy installation, making this unit a popular choice for both residential and commercial applications.

Lastly, the RAS-13GAVP-E excels in energy efficiency with its eco-friendly refrigerant options. It is equipped with a smart control system that allows users to monitor and adjust settings remotely, adding convenience and flexibility to its operation. This model is particularly beneficial for users looking to minimize their carbon footprint while enjoying the comfort of climate control.

Overall, Toshiba's lineup of air conditioning units, including RAS-B13GKVP-E, RAS-10GAVP-E, RAS-B10GKVP-E, RAS-16GKVP-E, and RAS-13GAVP-E, promises high performance, energy efficiency, and advanced technology. These features affirm Toshiba's commitment to creating a comfortable indoor environment while ensuring sustainability and user satisfaction.