10-3. Indoor Unit

10-3-1. Installation Place

A place which provides enough spaces around the indoor unit as shown in the diagram.

A place where there are no obstacle near the air inlet and outlet.

A place which allows easy installation of the piping to the outdoor unit.

A place which allows the front panel to be opened.

The indoor unit shall be installed so that the top of the indoor unit is positioned at least 2m in height.

Also, avoid putting anything on the top of the indoor unit.

CAUTION

Direct sunlight on the indoor unit wireless receiver should be avoided.

The microprocessor in the indoor unit should not be too close to r-f sources.

(For details, see the owner's manual.)

Remote controller

Should be placed where there are no obstacles, such as curtains, that may block the signal.

Do not install the remote controller in a place exposed to direct sunlight or close to a heating source, such as a stove.

Keep the remote controller at least 1 m away from the nearest TV set or stereo equipment.

(This is necessary to prevent image disturbances or noise interference.)

The location of the remote controller should be determined as shown below.

(Side view)

(Top view)

unit

Indoor unit

Indoor

 

Reception

 

Reception

Remote

range

range

controller

Remote controller

 

 

*: Axial distance

10-3-2. Drilling a Hole and Mounting Instal- lation Plate

Drilling a hole

When install the refrigerant pipes from the rear.

 

The center of the

 

pipe hole

 

Pipe

 

hole

 

65

42 mm

mm

 

Fig. 10-3-2

1.After determining the pipe hole position on the

installation plate ( ð ) drill the pipe hole (Ø65 mm) at a slight downward slant to the outdoor side.

NOTE :

When drilling into a wall that contains a metal lath, wire lath or metal plate, be sure to use a pipe hole brim ring sold separately.

Mounting the installation plate

Anchor bolt holes

25

mm

 

91

mm

 

Pipe hole

 

Pipe hole

Indoor unit

 

7 Mounting screw

1 Installation plate

Fig. 10-3-1

Fig. 10-3-3