Toshiba RAS-B10GKVP-E Operation flow and applicable data, etc, Description, In heating operation

Models: RAS-10GAVP-E RAS-16GAVP-E RAS-13GAVP-E RAS-B10GKVP-E RAS-B13GKVP-E RAS-B16GKVP-E

1 116
Download 116 pages 47.53 Kb
Page 32
Image 32

Item

6.Release protective control by tempera- ture of indoor heat exchanger

temperature

7˚C

exchanger

6˚C

 

Indoor heat

5˚C

 

temperature

55˚C

exchanger

50˚C

heatIndoor

46˚C

 

Operation flow and applicable data, etc.

Description

<In cooling/dry operation>

 

1) When temperature of the indoor

(Prevent-freezing control for indoor heat exchanger)

heat exchanger drops below 5°C,

the compressor speed is

In cooling/dry operation, the sensor of indoor heat

reduced. (P zone)

exchanger detects evaporation temperature and

2) When temperature of the indoor

controls the compressor speed so that temperature of

heat exchanger rises in the

the heat exchanger does not exceed the specified

range from 6°C to under 7°C, the

value.

 

 

compressor speed is kept.

 

 

 

 

(Q zone)

Usual cooling capacity control

 

3) When temperature of the indoor

 

 

heat exchanger rises to 7°C or

R

 

higher, the capacity control

 

When the value is

operation returns to the usual

 

control in cooling operation.

Q

in Q zone, the

(R zone)

compressor speed

 

is kept.

 

P

 

 

Reduction of compressor speed

 

 

<In heating operation>

 

1) When temperature of the indoor

(Prevent-overpressure control for refrigerating cycle)

heat exchanger rises in the

range from 50°C to 55°C, the

In heating operation, the sensor of indoor heat ex-

compressor speed is kept.

changer detects condensation temperature and controls

(Q zone)

the compressor speed so that temperature of the heat

When temperature of the indoor

exchanger does not exceed the specified value.

heat exchanger drops in the

 

 

 

 

range from 46°C to under 55°C,

 

 

the compressor speed is kept.

Reduction of compressor speed

 

(Q zone)

P

 

2) When temperature of the indoor

 

 

heat exchanger rises to 55°C or

 

 

higher, the compressor speed is

 

When the value is

reduced. (P zone)

Q

3) When temperature of the indoor

in Q zone, the

 

compressor speed

heat exchanger does not rise to

 

is kept.

50°C, or when it drops below to

 

 

46°C, the capacity control

R

 

operation returns to the usual

 

control in heating operation.

 

 

Usual heating capacity control

 

(R zone)

– 32 –