11-9-3. Indoor Unit (Other Parts)

No.

Part name

 

 

 

 

 

 

 

 

Checking procedure

 

 

 

 

 

 

1

Room temp. (TA) sensor

Disconnect the connector and measure the resistance value with tester.

 

Heat exchanger (TC) sensor

(Normal temp.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sensor

 

 

Temperature

10°C

20°C

 

25°C

 

30°C

40°C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TA, TC (k)

 

20.7

12.6

 

10.0

 

7.9

4.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Remote controller

Refer to 11-5-1. (5).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Louver motor

Measure the resistance value of each winding coil by using the tester.

 

MP24Z

(Under normal temp. 25°C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

White

 

 

 

 

 

 

 

 

 

Position

 

 

Resistance value

 

 

 

 

 

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yellow

 

 

 

 

 

 

 

 

 

1 to 2

 

 

 

 

 

 

 

 

 

 

2

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yellow

 

3

3

 

 

 

 

 

 

1 to 3

 

 

 

380 ± 40

 

 

 

 

Yellow

 

4

4

 

 

 

 

 

 

1 to 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yellow

 

5

5

 

 

 

 

 

 

1 to 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Indoor fan motor

Refer to 11-5-1. (3) and (4).

11-9-4. OutdoorUnit

No.

Part name

 

 

 

 

 

 

 

 

Checking procedure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Compressor

Measure the resistance value of each winding by using the tester.

 

 

 

(Model : DA111A1F-20F1)

 

 

 

 

Red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Position

Resistance value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Red - White

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.88 to 0.98

 

 

 

 

 

 

 

 

 

 

 

 

 

White - Black

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

White

 

 

Black

 

Black - Red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Under 20°C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Outdoor fan motor

Measure the resistance value of winding by using the tester.

 

 

 

(Model : ICF-140-43-4R)

 

 

 

 

Red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Position

Resistance value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Red - White

 

17 to 25k

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

White - Black

 

17 to 25k

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

White

 

 

Black

 

Black- Red

 

17 to 25k

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

4-way valve coil

Measure the resistance value of winding by using the tester.

 

 

 

(Model : VHV)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Resistance value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1435 ± 144

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Under 20°C

 

 

 

 

 

4

Pulse motor valve coil

Measure the resistance value of winding by using the tester.

 

 

 

(Model : CAM-MD12TF-6)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 W

 

 

 

 

Position

Resistance value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COM

 

6

R

 

 

 

 

Red - White

 

42 to 50k

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

White - Orange

 

42 to 50k

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Brown- Yellow

 

42 to 50k

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y BR BL

 

Brown- Blue

 

42 to 50k

 

 

 

 

 

 

 

 

COM

2 5

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Under 20°C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

Outdoor temperature sensor

Disconnect the connector, and measure resistance value with the tester.

 

(TO), discharge temperature

(Normal temperature)

 

 

 

 

 

 

 

 

 

sensor (TD), suction

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temperature

10°C

20°C

25°C

30°C

40°C

50°C

 

 

temperature sensor (TS),

 

Sensor

 

 

 

 

 

 

 

 

 

 

outdoor heat exchanger

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TD (kW)

 

 

 

100

64

50

41

27

18

 

 

temperature sensor (TE)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO,TS,TE (kW)

 

20.7

12.6

10.0

7.9

4.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

– 79 –

Page 79
Image 79
Toshiba RAS-B13GKVP-E, RAS-B16GKVP-E, RAS-B10GKVP-E Indoor Unit Other Parts, OutdoorUnit, Part name Checking procedure

RAS-10GAVP-E, RAS-16GAVP-E, RAS-13GAVP-E, RAS-B10GKVP-E, RAS-B13GKVP-E specifications

Toshiba has long been a renowned name in the world of air conditioning, delivering reliable and energy-efficient solutions that meet the demands of modern living. Among their innovative product line, the Toshiba RAS-B13GKVP-E, RAS-10GAVP-E, RAS-B10GKVP-E, RAS-16GKVP-E, and RAS-13GAVP-E stand out for their advanced features and cutting-edge technologies.

The RAS-B13GKVP-E is a powerful air conditioning unit designed for medium-sized rooms. It boasts a robust cooling capacity, ensuring comfort even during the hottest days. One of its standout features is the inverter technology, which optimizes energy consumption by adjusting the compressor speed according to the temperature, resulting in significant energy savings.

Next, the RAS-10GAVP-E is tailored for smaller spaces, offering efficient cooling and heating capabilities. It comes with an easy-to-use remote control and a user-friendly interface, allowing for effortless operation. The model also incorporates a quiet operation feature, making it suitable for bedrooms and study areas where noise can be a distraction.

The RAS-B10GKVP-E strikes a balance between size and efficiency, ideal for compact living spaces. Its dual cooling and heating function ensures year-round climate control. This model further enhances indoor air quality with its built-in filters, which capture dust and allergens, creating a healthier environment for occupants.

For larger areas, the RAS-16GKVP-E provides an impressive cooling capacity combined with turbo mode functionality. This feature enables rapid cooling of spaces during sweltering summer days. Its sleek design and compact form factor allow for easy installation, making this unit a popular choice for both residential and commercial applications.

Lastly, the RAS-13GAVP-E excels in energy efficiency with its eco-friendly refrigerant options. It is equipped with a smart control system that allows users to monitor and adjust settings remotely, adding convenience and flexibility to its operation. This model is particularly beneficial for users looking to minimize their carbon footprint while enjoying the comfort of climate control.

Overall, Toshiba's lineup of air conditioning units, including RAS-B13GKVP-E, RAS-10GAVP-E, RAS-B10GKVP-E, RAS-16GKVP-E, and RAS-13GAVP-E, promises high performance, energy efficiency, and advanced technology. These features affirm Toshiba's commitment to creating a comfortable indoor environment while ensuring sustainability and user satisfaction.