12-3. Outdoor Unit

No. Part name

Procedure

Remarks

Common 1. Detachment procedure

NOTE

Upper cabinet

Wear gloves for this job.

Water

Otherwise, you may injure your

proof

hands on the parts, etc.

cover

 

1) Stop operation of the air conditioner, and turn off the main switch of the breaker for air conditioner.

2) Remove the valve cover.

(ST1TØ4 × 8L 1 pc.)

• After removing screw, remove the valve cover pulling it downward.

3) Remove wiring cover (ST1TØ4 × 8L

 

2 pcs.), and then remove connecting

 

cable.

Valve cover

4)Remove the upper cabinet. (ST1TØ4 × 8L 5 pcs.)

After removing screws, remove the upper cabinet pulling it upward.

2.Attachment

1)Attach the water-proof cover.

 

NOTE

 

Insert the bent part

Bring into contact

 

 

into the rear panel

The water-proof cover must be

of the inverter

against these parts

 

 

attached without fail in order to

 

 

prevent rain water, etc. from entering

 

 

inside the indoor unit.

 

 

 

 

 

 

 

2) Attach the upper cabinet.

 

 

 

(ST1TØ4 × 8L 5 pcs.)

 

 

 

3) Perform cabling of connecting cable,

 

 

 

and attach the wiring cover.

Align the stitch line

Bend downward, and align

• Place the wiring cover over the

with the top edge

with the inside surface

opening used to work on the con-

of the front cabinet

of the front cabinet

 

 

 

necting wires of the side cabinet,

 

 

 

How to mount the water-proof cover

 

and secure it using the two fixing

 

screws (ST1TØ4 × 8L 2 pcs.).

 

 

 

At this point, the top cushion of the

 

 

 

wiring cover must be on the inside of

 

 

 

the opening.

 

 

 

4) Attach the valve cover.

 

 

 

(ST1TØ4 × 8L 1 pc.)

 

 

 

• Insert the upper part into the square

 

 

 

hole of the side cabinet, set hook

 

 

 

claws of the valve cover to square

 

 

 

holes (at three positions) of the main

 

 

 

unit, and attach it pushing upward.

 

 

 