Toshiba RAS-B13GKVP-E, RAS-B16GKVP-E Refrigerant Cycle Diagram, RAS-B10GKVP-E/RAS-10GAVP-E

Models: RAS-10GAVP-E RAS-16GAVP-E RAS-13GAVP-E RAS-B10GKVP-E RAS-B13GKVP-E RAS-B16GKVP-E

1 116
Download 116 pages 47.53 Kb
Page 19
Image 19

7. REFRIGERANT CYCLE DIAGRAM

7-1. Refrigerant Cycle Diagram

RAS-B10GKVP-E/RAS-10GAVP-E

PPressure measurement

Gauge attaching port

Vacuum pump connecting port

Deoxidized copper pipe

Outer dia. : 9.52mm

Thickness : 0.8mm

INDOOR UNIT

T1

Temp. measurement

 

 

 

 

 

 

 

 

Indoor heat

 

 

 

 

 

exchanger

 

 

 

 

 

 

TC

heightAllowable 10m:difference

lengthpipeAllowable

 

 

Cross flow fan

TA

Max.

: 25m

 

 

 

 

 

 

 

 

 

 

Min.

: 2m

Deoxidized copper pipe

 

 

Chargeless : 15m

Outer dia. : 6.35mm

 

 

Charge : 20g/m

Thickness : 0.8mm

 

 

 

(16 to 25m)

Sectional shape

 

 

 

 

 

of heat insulator

 

 

 

 

 

4-way valve (STF-0108Z)

TS

Temp. measurement T2

Muffler

Strainer

Muffler

Pulse motor

valve at liquid side

 

TD

(CAM-B22YGTF-3)

 

Compressor

Strainer

DA111A1F-20F1

TO

Outdoor heat exchanger

 

 

 

 

 

 

 

 

 

 

TE

 

Refrigerant amount : 0.82kg

 

 

 

 

 

Propeller fan

 

 

OUTDOOR UNIT

 

NOTE :

 

Gas leak check position

 

 

 

 

 

 

Refrigerant flow (Cooling)

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant flow (Heating)

NOTE :

The maximum pipe length of this air conditioner is 25 m. When the pipe length exceeds 15m, the additional charging of refrigerant, 20g per 1m for the part of pipe exceeded 15m is required. (Max. 200g)

– 19 –

Page 19
Image 19
Toshiba RAS-B13GKVP-E, RAS-B16GKVP-E, RAS-13GAVP-E, RAS-16GAVP-E Refrigerant Cycle Diagram, RAS-B10GKVP-E/RAS-10GAVP-E