10-5. Test Operation

10-5-1. Gas Leak Test

Check the flare nut connections for gas leaks with a gas leak detector and/or soapy water.

10-5-4. Remote Controller Selector Switch Setting

Remote controller selector switch

Check places for

Valve cover

• If two indoor units are installed in the same room

or adjoining rooms, the second unit can inadvert-

flare nut connections (indoor unit)

Electric parts

Check places for outdoor unit

Fig. 10-5-1

10-5-2. Test Operation

To test the system, press and hold RESET button for 10 sec. (There will be one short beep.)

ently receive a remote controller signal and start

operation when operating the first unit. This can be

prevented by setting one of the indoor units and

the corresponding remote controller to the B

setting (the A setting is the default setting).

1. Setting the selector switch on the main unit

• Remove the front panel, and then set the

selector switch to “B”.

• After making the switch setting, remount the

front panel.

2. Setting the remote controller

1) Slide open the remote controller cover and

remove the batteries.

2) Cut the jumper wire inside the battery

compartment using nippers.

• The jumper wire should not remain in

contact after being cut. Also, be careful

not to let plastic scraps, jumper wire

cuttings or other debris enter the inside of

the remote controller.

3)Insert the batteries. “B” appears in the remote controller display.

3.Check that the indoor unit can be operated by the modified remote controller.

Position of remote controller selector switch

Fig. 10-5-2

10-5-3. Auto Restart Setting

This product is designed so that, after a power failure, it can restart automatically in the same operating mode as before the power failure.

Information

The product was shipped with Auto Restart function in the OFF position.

Selector switch

Fig. 10-5-3

Turn it ON as required.

HiPOWER ECO MEMO

1.3.5.9H

SWING FIX FAN SLEEP

CLRSET

Cutting direction

Jumper wire

How to Set the Auto Restart

Press and hold the RESET button for about 3

 

seconds. After 3 seconds, three short electric

 

beeps will be heard to inform you that the Auto

 

Restart has been selected.

To cancel the Auto Restart, follow the steps

 

described in the section Auto Restart Function on

CLOCK

RESET

ON OFF

CHECK

When switching between settings “A” and “B”, always switch the indoor unit board and the remote controller as a pair.

(Otherwise, the indoor unit will not accept the remote controller’s signals.)

Owner’s Manual.

Fig. 10-5-4

– 59 –

Page 59
Image 59
Toshiba RAS-10GAVP-E, RAS-B16GKVP-E Test Operation, Information, Gas Leak Test, Remote Controller Selector Switch Setting