Item

9.Louver control

1)Louver position

Operation flow and applicable data, etc.

Description

This function controls the air direction of the indoor unit.

The position is automatically controlled according to the operation mode (COOL/HEAT).

The set louver position is stored in memory by the microcomputer, and the louver returns to the stored position when the next operation is performed. (Cooling/heating memory position)

The angle of the louver is indicated as the horizontal angle is 0°.

When the louver closes fully, it directs approx. 49° upward.

1) Louver position in cooling operation

Louver angle

Horizontal

(0˚)

 

Powerful

Room temp. (Ta) < Set temp. (Tsc) + 3.5

Room temp. (Ta) Set temp. (Tsc) + 3.5

Initial setting of “Cooling storage position” Louver : Directs downward (9˚)

Initial setting of “Cooling storage position” Louver : Directs downward (9˚)

“Inclined blowing”

Louver : Directs downward (14˚)

Cooling/AUTO (COOL)/DRY operation

 

 

Powerful YES

Room temp. NO

 

 

operation

 

Set temp. +3.5

 

 

 

 

 

 

 

 

NO

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

Cooling memory

 

 

 

 

 

 

position

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling memory

position

Inclined blowing

NO

Room temp. Set temp. +3.5

YES

2) Louver position in heating operation

Heating operation/

ECO operation

Room temp. (Ta) < Set temp. (Tsc) – 3

Room temp. (Ta) Set temp. (Tsc) – 3

AUTO (HEAT)

or 25 minutes after start of operation

 

 

 

Initial setting of “Heating storage position” Louver : Directs downward (76˚)

“Heating storage position” Louver : Directs downward (76˚)

“Cooling storage position” Louver : Directs downward (9˚)

Heating operation

 

 

ECO YES

Room temp. NO

 

 

 

 

operation

 

Set temp. –3.0

 

 

 

NO

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating memory

 

 

 

 

 

 

position

 

 

 

 

 

 

 

 

 

 

 

 

 

Horizontal

position

Heating memory

position

NO

Room temp. Set temp. –3.0

YES

2) Air direction adjustment

Air direction

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Horizontal

 

Inclined

 

Blowing

 

Inclined

 

Horizontal

 

 

 

 

blowing

 

blowing

 

downward

 

blowing

 

blowing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3) Swing

Swing operation is performed in width 35° with the stop position as

 

 

the center.

 

If the stop position exceeds either upper or lower limit position,

 

 

swing operation is performed in width 35° from the limit which the

 

 

stop position exceeded.

 

 

 

The louver position can be arbitrarily set up by pressing [FIX] button.

Swing

When pressing [SWING] button during operation, the louver starts swinging.

– 34 –

Page 34
Image 34
Toshiba RAS-16GAVP-E This function controls the air direction of the indoor unit, Louver position in cooling operation

RAS-10GAVP-E, RAS-16GAVP-E, RAS-13GAVP-E, RAS-B10GKVP-E, RAS-B13GKVP-E specifications

Toshiba has long been a renowned name in the world of air conditioning, delivering reliable and energy-efficient solutions that meet the demands of modern living. Among their innovative product line, the Toshiba RAS-B13GKVP-E, RAS-10GAVP-E, RAS-B10GKVP-E, RAS-16GKVP-E, and RAS-13GAVP-E stand out for their advanced features and cutting-edge technologies.

The RAS-B13GKVP-E is a powerful air conditioning unit designed for medium-sized rooms. It boasts a robust cooling capacity, ensuring comfort even during the hottest days. One of its standout features is the inverter technology, which optimizes energy consumption by adjusting the compressor speed according to the temperature, resulting in significant energy savings.

Next, the RAS-10GAVP-E is tailored for smaller spaces, offering efficient cooling and heating capabilities. It comes with an easy-to-use remote control and a user-friendly interface, allowing for effortless operation. The model also incorporates a quiet operation feature, making it suitable for bedrooms and study areas where noise can be a distraction.

The RAS-B10GKVP-E strikes a balance between size and efficiency, ideal for compact living spaces. Its dual cooling and heating function ensures year-round climate control. This model further enhances indoor air quality with its built-in filters, which capture dust and allergens, creating a healthier environment for occupants.

For larger areas, the RAS-16GKVP-E provides an impressive cooling capacity combined with turbo mode functionality. This feature enables rapid cooling of spaces during sweltering summer days. Its sleek design and compact form factor allow for easy installation, making this unit a popular choice for both residential and commercial applications.

Lastly, the RAS-13GAVP-E excels in energy efficiency with its eco-friendly refrigerant options. It is equipped with a smart control system that allows users to monitor and adjust settings remotely, adding convenience and flexibility to its operation. This model is particularly beneficial for users looking to minimize their carbon footprint while enjoying the comfort of climate control.

Overall, Toshiba's lineup of air conditioning units, including RAS-B13GKVP-E, RAS-10GAVP-E, RAS-B10GKVP-E, RAS-16GKVP-E, and RAS-13GAVP-E, promises high performance, energy efficiency, and advanced technology. These features affirm Toshiba's commitment to creating a comfortable indoor environment while ensuring sustainability and user satisfaction.