Toshiba RAS-B16GKVP-E, RAS-B13GKVP-E How To Diagnose The Trouble, Caution High Voltagen

Models: RAS-10GAVP-E RAS-16GAVP-E RAS-13GAVP-E RAS-B10GKVP-E RAS-B13GKVP-E RAS-B16GKVP-E

1 116
Download 116 pages 47.53 Kb
Page 60
Image 60

11. HOW TO DIAGNOSE THE TROUBLE

The pulse motor circuits are mounted to both indoor and outdoor units. Therefore, diagnose troubles according to the trouble diagnosis procedure as described below. (Refer to the check points in servicing written on the wiring diagrams attached to the indoor/outdoor units.)

Table 11-1

No.

Troubleshooting Procedure

Page

 

 

 

1

First Confirmation

62

 

 

 

2

Primary Judgment

63

 

 

 

3

Judgment by Flashing LED of Indoor Unit

63

 

 

 

4

Self-Diagnosis by Remote Controller

64

 

 

 

5

Judgment of Trouble by Every Symptom

67

 

 

 

No.

Troubleshooting Procedure

Page

 

 

 

6

How to Check Simply the Main Parts

72

 

 

 

7

Troubleshooting

73

 

 

 

8

How to Diagnose Trouble in Outdoor Unit

75

 

 

 

9

How to Check Simply the Main Parts

76

 

 

 

10

How to Simply Judge Whether Outdoor

81

Fan Motor is Good or Bad

 

 

 

 

 

KPrecautions when handling the new inverter (3DV Inverter)

CAUTION: HIGH VOLTAGEN

The high voltage circuit is incorporated.

Be careful to do the check service, as the electric shock may be caused in case of touching parts on the P.C. board by hand.

The new inverter (3DV inverter) will be incorporated starting with this unit.

(3DV: 3-shunt Discrete Vector control)

KThe control circuitry has an uninsulated construction.

 

 

G-Tr

Compressor

 

 

FET

Fan motor

 

Photocoupler

 

 

 

(6IN1)

 

Shared potential

MCU

 

 

 

 

Hall device

 

 

 

 

 

 

Photocoupler

Shared potential

JAVP-E series (insulated type)

 

 

 

IGBT × 6

Compressor

 

 

 

 

Fan motor

 

Driver

Amplifier

FET × 6

 

MCU

Driver

 

 

 

 

 

 

 

 

Amplifier

 

 

 

GAVP-E, EAVP-E series (uninsulated type)

Fig. 11-1

– 60 –

Page 60
Image 60