Appendix

No.

 

 

 

 

 

Photo / Explanatory diagram

Procedure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cord heater installation work

 

2

Drill a hole on the outdoor unit base plate, and fix the cord heater to the outdoor unit base plate using P-shape

clamp.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connect the cord heater cables.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Using a motor drill, etc., drill Ø3.2 holes on the outdoor unit base plate. (12 positions) See Appendix-10 for the

2-1

additional hole positions.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

These holes are used to fix the cord heater to the outdoor unit base plate with P-shape clamp.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Insert the PVC tube into the cord heater.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This tube is designed to protect the cord heater from

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the fixing screws used to secure the anchoring feet.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

As shown in the left figure, install the cord heater

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1.5m) to the outdoor unit base plate by using P-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

shape clamp and screws (Self-tapping screw type-B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ø4 × 6mm, stainless).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pay attention to the direction of P-shape clamp so

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

that it is set to the same direction in the left figure.

 

 

 

 

 

 

 

 

 

 

The PVC tube must be inserted

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

into the cord heater between

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the fixing screws in order to

* If the drain port is frozen due to installation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

protect the cord heater from

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

status, etc., draw around the cord heater so that

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-2

 

 

 

 

 

 

 

 

 

 

 

these screws.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Under no circumstances must

 

 

 

the end part of the heater is inserted into the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PVC tube

 

 

 

 

 

 

 

 

drain port. In this case, add some fixing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the tube be allowed to ride over

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the tip of the fixing screws.

positions to fix the cord heater surely.

 

 

 

 

Ø9.1 P-shape clamp

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* The end part from the marked part of the cord

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

heater heats up. When there is the heating part

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

near the electric parts box, a fire may generate.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Be sure to set the heating part on the outdoor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

unit base plate at the fan room side or near it.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(within 20cm from the outdoor unit base plate)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enlarged

* Be careful that the cord heater does not hit the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

fan.

 

 

 

 

Heating part

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

marked part

Fix the cord heater without any loosening or sag.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

Drill a hole on the side cabinet (R) for fixing the

 

 

 

 

 

 

 

 

 

 

Added hole 2-

φ

 

 

 

 

 

 

thermostat fixing plate.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

Ø5 hole at two positions

When drilling a hole on the side cabinet (R), be

 

46

sure not to damage the cabinet.

7

2-3

Side cabinet (R)

Appendix-6

Page 111
Image 111
Toshiba RAS-13GAVP-E, RAS-B16GKVP-E, RAS-B13GKVP-E, RAS-B10GKVP-E, RAS-16GAVP-E, RAS-10GAVP-E service manual Appendix-6

RAS-10GAVP-E, RAS-16GAVP-E, RAS-13GAVP-E, RAS-B10GKVP-E, RAS-B13GKVP-E specifications

Toshiba has long been a renowned name in the world of air conditioning, delivering reliable and energy-efficient solutions that meet the demands of modern living. Among their innovative product line, the Toshiba RAS-B13GKVP-E, RAS-10GAVP-E, RAS-B10GKVP-E, RAS-16GKVP-E, and RAS-13GAVP-E stand out for their advanced features and cutting-edge technologies.

The RAS-B13GKVP-E is a powerful air conditioning unit designed for medium-sized rooms. It boasts a robust cooling capacity, ensuring comfort even during the hottest days. One of its standout features is the inverter technology, which optimizes energy consumption by adjusting the compressor speed according to the temperature, resulting in significant energy savings.

Next, the RAS-10GAVP-E is tailored for smaller spaces, offering efficient cooling and heating capabilities. It comes with an easy-to-use remote control and a user-friendly interface, allowing for effortless operation. The model also incorporates a quiet operation feature, making it suitable for bedrooms and study areas where noise can be a distraction.

The RAS-B10GKVP-E strikes a balance between size and efficiency, ideal for compact living spaces. Its dual cooling and heating function ensures year-round climate control. This model further enhances indoor air quality with its built-in filters, which capture dust and allergens, creating a healthier environment for occupants.

For larger areas, the RAS-16GKVP-E provides an impressive cooling capacity combined with turbo mode functionality. This feature enables rapid cooling of spaces during sweltering summer days. Its sleek design and compact form factor allow for easy installation, making this unit a popular choice for both residential and commercial applications.

Lastly, the RAS-13GAVP-E excels in energy efficiency with its eco-friendly refrigerant options. It is equipped with a smart control system that allows users to monitor and adjust settings remotely, adding convenience and flexibility to its operation. This model is particularly beneficial for users looking to minimize their carbon footprint while enjoying the comfort of climate control.

Overall, Toshiba's lineup of air conditioning units, including RAS-B13GKVP-E, RAS-10GAVP-E, RAS-B10GKVP-E, RAS-16GKVP-E, and RAS-13GAVP-E, promises high performance, energy efficiency, and advanced technology. These features affirm Toshiba's commitment to creating a comfortable indoor environment while ensuring sustainability and user satisfaction.