Toshiba RAS-13GAVP-E, RAS-B16GKVP-E Operation flow and applicable data, etc, Description, Purpose

Models: RAS-10GAVP-E RAS-16GAVP-E RAS-13GAVP-E RAS-B10GKVP-E RAS-B13GKVP-E RAS-B16GKVP-E

1 116
Download 116 pages 47.53 Kb
Page 39
Image 39

 

Item

 

 

Operation flow and applicable data, etc.

 

Description

 

 

 

 

 

 

 

 

 

 

15. Clean operation

 

 

 

1. Purpose

 

 

 

 

 

 

 

 

 

The clean operation is to minimize the

 

 

 

 

 

 

 

 

 

growth of mold, bacteria etc. by running

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the fan and drying so as to keep the

 

 

Unit now performing cooling or dry operation

 

 

inside of the air conditioner clean.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clean operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When the cooling or dry operation shuts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

down, the unit automatically starts the

 

 

 

 

Press “STOP” button

 

 

 

 

 

 

 

 

 

 

clean operation which is then performed

 

 

 

 

 

 

 

 

 

for the specified period based on duration

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of the operation which was performed

 

 

 

 

 

 

 

 

 

prior to the shutdown, after which the

 

Only S.CLEAN indicator lights, and clean operation starts

 

 

clean operation stops.

 

 

 

 

 

 

 

 

 

(The clean operation is not performed

 

 

 

 

 

 

 

 

 

after a heating operation.)

 

 

 

 

 

 

 

 

2. Operation

 

 

 

 

 

 

 

 

 

 

 

 

Time set now elapses

 

 

 

 

 

 

 

 

 

1) When the stop signal from the remote

 

 

 

 

 

 

 

 

 

controller is received, the S.CLEAN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

indicator (green) on the main body

 

 

 

 

 

 

 

 

 

lights, and the clean operation starts.

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation stops

 

 

 

(Neither the OPERATION indicator nor

 

 

 

 

 

 

 

 

 

the TIMER indicator light.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2) The period of the clean operation is

 

 

 

 

 

 

 

 

 

determined by the duration of the

 

 

 

 

 

 

 

 

 

operation performed prior to the

 

 

 

• During clean operations: The louver opens

 

reception of the stop code.

 

 

 

 

slightly. The indoor fan operates continuously at

 

3) After the clean operation has been

 

 

 

 

a speed of 260 rpm.

 

 

 

performed for the specified period, the

 

 

 

 

Clean operation times

 

 

 

unit stops operating.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation mode

Operation time

 

Clean operation time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Up to 10 minutes

 

No clean operation

 

 

 

 

 

 

 

 

performed (0 minutes)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling: Auto (cooling) Dry

From 10 minutes up

 

2 hours

 

 

 

 

 

 

 

to 1 hour

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 hour or longer

 

4 hours

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating: Auto (heating)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auto (fan only)

No clean operation performed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shutdown

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To stop an ongoing clean operation at any time

Press the start/stop button on the remote controller twice during the clean operation. (After pressing the button for the first time, press it for the second time without delay (within 10 minutes).)

– 39 –