(3) Check procedures

Table 11-9-1

No.

Procedure

 

Check points

 

Causes

 

 

 

 

1

Turn off the power supply breaker

Check whether or not the fuse (F01)

Impulse voltage was applied or the

 

and remove the P.C. board

is blown.

 

 

 

 

indoor fan motor short-circuited.

 

assembly from electronic parts

 

 

 

 

 

 

 

 

 

 

 

base. Remove the connecting

 

 

 

 

 

 

 

 

 

 

 

cables from the terminal block.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Remove the connector of the

Check power supply voltage :

1.

The terminal block or the crossover

 

motor and turn on the power

1.

Between No. 1 and No. 3 of CN23

 

cable is connected wrongly.

 

supply breaker. If OPERATION

 

(AC 220–240V)

 

2.

The capacitor (C01), line filter

 

indicator flashes (once per

2.

Between

and

 

 

of C03

 

(L01), resistor (R05), or the diode

 

second), it is not necessary to

 

 

 

 

(DC 310–340V)

 

 

(DB01) is defective.

 

check steps (1 to 3) in the right

3.

Between

 

 

of C10 and output

3.

IC01, IC08 and T01 are defective.

 

next column.

 

 

 

 

 

 

side of IC08 (DC 15V)

4.

IC01, IC08 and T01 are defective.

 

 

 

 

 

4.

Between 12V and GND

5.

IC01, IC08, IC07 and T01 are

 

 

5.

Between 5V and GND

 

defective.

 

 

 

 

 

 

 

 

3

Push [START/STOP] button once

Check power supply voltage :

IC03 and IC04 are defective.

 

to start the unit. (Do not set the

1.

Between CN21 and

 

 

 

 

mode to On-Timer operation.)

 

No. 1 of CN23 (DC 15–60V)

 

 

 

 

 

 

 

 

 

 

4

Shorten the restart delay timer

Check whether or not all indicators

The indicators are defective or the

 

and start unit.

(OPERATION, TIMER, FILTER,

housing assembly (CN13) is defective.

 

 

PURE) are lit for 3 seconds and they

 

 

 

 

return to normal 3 seconds later.

 

 

 

 

 

 

 

 

5

Push [START/STOP] button once

1.

Check whether or not the com-

1.

The temperature of the indoor heat

 

to start the unit,

 

pressor operates.

 

 

exchanger is extremely low.

 

• Shorten the restart delay timer.

2.

Check whether or not the OP-

2.

The connection of the heat ex-

 

• Set the operation mode to

 

ERATION indicator flashes.

 

changer sensor is loose.

 

COOL.

 

 

 

 

 

 

 

 

 

(The connector is disconnected.)

 

• Set the fan speed level to

 

 

 

 

 

 

 

 

 

(CN01)

 

 

 

 

 

 

 

 

 

3.

The heat exchanger sensor and the

 

AUTO.

 

 

 

 

 

 

 

 

 

• Set the preset temperature

 

 

 

 

 

 

 

 

 

P.C. board are defective.

 

 

 

 

 

 

 

 

 

 

(Refer to Table 11-4-1.)

 

much lower than the room

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.

The main P.C. board is defective.

 

temperature. (The unit (com-

 

 

 

 

 

 

 

 

 

pressor) operates continuously

 

 

 

 

 

 

 

 

 

 

 

in the above condition.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

If the above condition (No. 5) still

1.

Check whether or not the com-

1.

The temperature of the indoor heat

 

continues, start the unit in the

 

pressor operates.

 

 

exchanger is extremely high.

 

following condition.

2.

Check whether or not the OP-

2.

The connection of the heat ex-

 

• Set the operation mode to

 

ERATION indicator flashes.

 

changer sensor short-circuited.

 

HEAT.

 

 

 

 

 

 

 

 

 

(CN01)

 

• Set the preset temperature

 

 

 

 

 

 

 

 

3.

The heat exchanger sensor and the

 

much higher than room tem-

 

 

 

 

 

 

 

 

 

P.C. board are defective.

 

perature.

 

 

 

 

 

 

 

 

 

(Refer to Table 11-4-1.)

 

 

 

 

 

 

 

 

 

 

4.

The main P.C. board is defective

 

 

 

 

 

 

7

Connect the motor connector to

1.

Check it is impossible to detect

1.

The indoor fan motor is defective.

 

the motor and turn on the power

 

the voltage (DC 15V) between 3

 

(Protected operation of P.C. board.)

 

supply.

 

and 4 of the motor terminals.

2.

The P.C. board is defective.

 

Start the unit the following

2.

The motor does not operate or

3.

The connection of the motor

 

condition.

 

the fan motor does not rotate with

 

connector is loose.

 

• Set the fan speed level to HIGH.

 

high speed.

 

 

 

 

 

 

 

(The unit (compressor) operates

 

(But it is possible to receive the

 

 

 

continuously in the above

 

signal from the remote controller.)

 

 

 

condition in No. 5.)

3.

The motor rotates but vibrates

 

 

 

 

 

strongly.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

– 77 –

Page 77
Image 77
Toshiba RAS-10GAVP-E, RAS-B16GKVP-E, RAS-B13GKVP-E, RAS-B10GKVP-E Check procedures, Procedure Check points Causes

RAS-10GAVP-E, RAS-16GAVP-E, RAS-13GAVP-E, RAS-B10GKVP-E, RAS-B13GKVP-E specifications

Toshiba has long been a renowned name in the world of air conditioning, delivering reliable and energy-efficient solutions that meet the demands of modern living. Among their innovative product line, the Toshiba RAS-B13GKVP-E, RAS-10GAVP-E, RAS-B10GKVP-E, RAS-16GKVP-E, and RAS-13GAVP-E stand out for their advanced features and cutting-edge technologies.

The RAS-B13GKVP-E is a powerful air conditioning unit designed for medium-sized rooms. It boasts a robust cooling capacity, ensuring comfort even during the hottest days. One of its standout features is the inverter technology, which optimizes energy consumption by adjusting the compressor speed according to the temperature, resulting in significant energy savings.

Next, the RAS-10GAVP-E is tailored for smaller spaces, offering efficient cooling and heating capabilities. It comes with an easy-to-use remote control and a user-friendly interface, allowing for effortless operation. The model also incorporates a quiet operation feature, making it suitable for bedrooms and study areas where noise can be a distraction.

The RAS-B10GKVP-E strikes a balance between size and efficiency, ideal for compact living spaces. Its dual cooling and heating function ensures year-round climate control. This model further enhances indoor air quality with its built-in filters, which capture dust and allergens, creating a healthier environment for occupants.

For larger areas, the RAS-16GKVP-E provides an impressive cooling capacity combined with turbo mode functionality. This feature enables rapid cooling of spaces during sweltering summer days. Its sleek design and compact form factor allow for easy installation, making this unit a popular choice for both residential and commercial applications.

Lastly, the RAS-13GAVP-E excels in energy efficiency with its eco-friendly refrigerant options. It is equipped with a smart control system that allows users to monitor and adjust settings remotely, adding convenience and flexibility to its operation. This model is particularly beneficial for users looking to minimize their carbon footprint while enjoying the comfort of climate control.

Overall, Toshiba's lineup of air conditioning units, including RAS-B13GKVP-E, RAS-10GAVP-E, RAS-B10GKVP-E, RAS-16GKVP-E, and RAS-13GAVP-E, promises high performance, energy efficiency, and advanced technology. These features affirm Toshiba's commitment to creating a comfortable indoor environment while ensuring sustainability and user satisfaction.