Installation Instructions (cont'd)

Temperature-Pressure

Relief Valve

A WARNING

At the time ofmanufacture thiswater heaterwas providedwith a combinationtemperature-pressuresreliefvalvecertifiedby a nationallyrecognizedtestinglaboratorythat maintainsperiodic inspectionof productionof listedequipment or materials,as meetingthe requirementsfor ReliefValvesand AutomaticGas ShutoffDevicesfor Hot Water SupplySystems,and the latest edition of ANSI Z21.22 and the code requirements of ASHE. If

replaced,the valvemustmeet the requirementsof localcodes but not lessthan a combinationtemperature andpressurerelief valvecertifiedasmeetingthe requirementsfor ReliefValvesand

AutomaticGasShutoffDevicesfor Hot Water SupplySystems, ANSI Z21.22 by a nationally recognizedtestinglaboratorythat

maintainsperiodicinspectionof productionof listedequipment or materials.

The valvemust be markedwith a maximum set pressurenot to exceed the marked hydrostaticworking pressure of the

water heater (150 Ibsdsq.in.) and a dischargecapacity not lessthan the water heater input rate as shownon the model

rating plate.(Electric heaters - watts dividedby 1000x 3415 equalBTU/Hr. rate,)

Yourlocaljurisdictionalauthority,while mandatingthe useof a temperature-pressurereliefvalvecomplyingwith ANSI Z21.22 and ASME,mayrequire a vane model differentfrom the onefur- nishedwith the water heater.

Compliancewith suchlocalrequirements must be satisfiedby the installeror end user of the water heater with a locallypre- scribed temperature-pressurereliefvalveinstalledin the desig-

natedopeningin the water heater in placeof the factoryfur- nishedvalve.

Forsafeoperationofthe water heater,the reliefvalvemustnot

beremovedfrom it'sdesignatedopeningor plugged.

The temperature-pressurereliefvalvemustbe installeddirectly intothe fittingofthe water heaterdesignatedfor the relief valve. Positionthe valvedownwardand providetubing sothat anydis-

chargewill exit onlywithin 6 inchesabove,or at any distance belowthe structuralfloor.Be certainthat no contactis made

with anyliveelectricalpart. The dischargeopeningmustnot be blockedor reduced in sizeunder anycircumstances. Excessive length,over30 feet, or useof more than four elbowscan cause restriction andreducethedischargecapacityofthe valve.

No valveor other obstructionisto be placedbetween the relief valveand the tank. Do not connecttubingdirectlyto discharge drain unlessa 6" air gap is provided.To preventbodilyinjury, hazard to life, or property damage,the relief valve must be allowedto dischargewater in quantitiesshouldcircumstances demand. If the dischargepipe is not connectedto a drain or

i other suitable means, the water flow may cause property damage.

:The DischargePipe:

:Must not be smallerin sizethan the outlet pipesizeofthe valve,or haveanyreducing couplingsor other restrictions. Must not be pluggedor blocked.

Must be of material listedfor hot water distribution.

!Must be installedsoasto allow completedrainageof both

the temperature-pressurereliefvalve, and the discharge pipe.

tMustterminate at an adequatedrain.

Mustnot haveanyvalvebetween the rolief valveand tank.

&WARNING

The temperature-pressure relief valve must be manually operated at least once a year. Caution should be taken to ensure that (I) no one is in front of or around the outlet of the temperature-pressure relief valve discharge line, and (2) the water manually dischargedwill not cause any bodily injury or property damage becausethe water may be extremely hot.

If after manually operating the valve, it fails to completely reset and continues to release water, immediately, close the cold water inlet to the water heater, follow the drain-

ing instructions, and replace the temperature-pressure relief valve with a new one.

HOT

.TEMPERATURE- PRESSURE

RELIEF VALVE

(Do not cap or plug)

6" AIR GAP

FLOOR DRAIN

T&P RELIEF

VALVE PROBE

TEMPERATURE-

INTO TANK

PRESSURE

RELIEF VALVE

T&P

SHANK

NIPPLE ''' LENGTH

If a shor_ shank (le_s than 2") temperature-pressureielie$valve is to be installed (as shown),a nippleand couplingmust _ used

_f a longshank (2" or longer)is to be inst_led, de not use the nipple and co_ng

InStallTemperalu_Pressurep_otectNeeou_nent _quired by _c_.aleodes,b_ notlessthan a comb+ha.

bo,, Temperature Pressure Relief Valve certified as meeting the requi;ements for Relief Valves and

AutomaticGas Shutoff_ 1o'Hot-water Supd.ySystems¸A_S 721 22by _ na_0nallyecc_zed test.

mg lab_aton/that _ periodc_specaca ofpn:ducbt_ol Im_:l equprnemor marshalsTheva;ve

rn_ beode_l_, pmV,ded _€_hM:ing, c<_ mstal_d soI_ d_so3an_ecanexatonlyw_n 6 _ch_s

above,ot at anydistancebelowB-,as_tural IIo_, andcannotcontactanylive electricalpa_ Forsaleope_on c+If_ wate_heater,the gekefValvem_str,_ bet_',o_d or p_gge¢

See rnar_Jalheading- Temperatule-pressureRel+elValve for installal_ona_ maintenanceof Relief Valve¸clschargepipeandc6_etsafetypre_ubor,s

9

Page 9
Image 9
Kenmore 153.320493 HT, 153.320492 HT, 153.320893 HT, 153.320892 HT, 153.320592 HT Temperature-Pressure, Relief Valve

153.320592 HT, 153.320692 HT, 153.320893 HT, 153.320492 HT, 153.320892 HT specifications

Kenmore has long been synonymous with quality home appliances, and the Kenmore 153.320593 HT, 153.320492 HT, 153.320392 HT, 153.320393 HT, and 153.320493 HT models continue this tradition with their advanced features and technologies. These models are designed specifically for convenience, efficiency, and performance, catering to a variety of household needs.

One of the standout features of the Kenmore 153 series is its efficient heating technology, which ensures that water is heated quickly and evenly. This is essential for both cleaning and cooking applications, making it a versatile addition to any kitchen. The heating elements are designed for durability, promoting longevity and reducing the frequency of replacements.

These models also boast a user-friendly control panel, which simplifies operation. The intuitive design makes it easy for users to select their desired temperature and washing cycles. Furthermore, some units in this series are equipped with digital displays that provide real-time feedback on the appliance's operation, allowing homeowners to monitor performance at a glance.

Energy efficiency is another hallmark of the Kenmore 153 series. With the rising concerns about energy consumption, these models incorporate technology that minimizes electrical usage without sacrificing performance. This not only aligns with sustainability goals but also helps homeowners save on their energy bills.

Another impressive characteristic of the Kenmore 153 models is their built-in safety features. Overheat protection and automatic shut-off mechanisms are standard across the series, ensuring peace of mind when the appliance is in operation. These safety measures are particularly valuable in households with children or pets.

In terms of design, the Kenmore models reflect a modern aesthetic, with sleek finishes that complement a variety of kitchen decors. Their compact size ensures that they fit seamlessly into limited spaces, making them ideal for both small apartments and spacious homes.

Additionally, the durable construction of these appliances is designed to withstand the rigors of daily use. The materials used are resistant to wear and tear, ensuring that the units maintain their functionality and appearance over time.

Overall, the Kenmore 153.320593 HT, 153.320492 HT, 153.320392 HT, 153.320393 HT, and 153.320493 HT models represent a blend of innovation, practicality, and style. With their advanced features, energy efficiency, and commitment to safety, these appliances stand out as an excellent choice for those seeking dependable performance in their everyday tasks.