Installation Instructions (cont'd)
Temperature-Pressure
Relief Valve
A WARNING
At the time ofmanufacture thiswater heaterwas providedwith a
replaced,the valvemustmeet the requirementsof localcodes but not lessthan a combinationtemperature andpressurerelief valvecertifiedasmeetingthe requirementsfor ReliefValvesand
AutomaticGasShutoffDevicesfor Hot Water SupplySystems, ANSI Z21.22 by a nationally recognizedtestinglaboratorythat
maintainsperiodicinspectionof productionof listedequipment or materials.
The valvemust be markedwith a maximum set pressurenot to exceed the marked hydrostaticworking pressure of the
water heater (150 Ibsdsq.in.) and a dischargecapacity not lessthan the water heater input rate as shownon the model
rating plate.(Electric heaters - watts dividedby 1000x 3415 equalBTU/Hr. rate,)
Yourlocaljurisdictionalauthority,while mandatingthe useof a
Compliancewith suchlocalrequirements must be satisfiedby the installeror end user of the water heater with a locallypre- scribed
natedopeningin the water heater in placeof the factoryfur- nishedvalve.
Forsafeoperationofthe water heater,the reliefvalvemustnot
beremovedfrom it'sdesignatedopeningor plugged.
The
chargewill exit onlywithin 6 inchesabove,or at any distance belowthe structuralfloor.Be certainthat no contactis made
with anyliveelectricalpart. The dischargeopeningmustnot be blockedor reduced in sizeunder anycircumstances. Excessive length,over30 feet, or useof more than four elbowscan cause restriction andreducethedischargecapacityofthe valve.
No valveor other obstructionisto be placedbetween the relief valveand the tank. Do not connecttubingdirectlyto discharge drain unlessa 6" air gap is provided.To preventbodilyinjury, hazard to life, or property damage,the relief valve must be allowedto dischargewater in quantitiesshouldcircumstances demand. If the dischargepipe is not connectedto a drain or
i other suitable means, the water flow may cause property damage.
:The DischargePipe:
:Must not be smallerin sizethan the outlet pipesizeofthe valve,or haveanyreducing couplingsor other restrictions. Must not be pluggedor blocked.
•Must be of material listedfor hot water distribution.
!Must be installedsoasto allow completedrainageof both
the
tMustterminate at an adequatedrain.
Mustnot haveanyvalvebetween the rolief valveand tank.
&WARNING
The
If after manually operating the valve, it fails to completely reset and continues to release water, immediately, close the cold water inlet to the water heater, follow the drain-
ing instructions, and replace the
HOT
.TEMPERATURE- PRESSURE
RELIEF VALVE
(Do not cap or plug)
6" AIR GAP
FLOOR DRAIN
T&P RELIEF
VALVE PROBE | TEMPERATURE- |
INTO TANK | PRESSURE |
RELIEF VALVE |
T&P
SHANK
NIPPLE ''' LENGTH
•If a shor_ shank (le_s than 2")
•_f a longshank (2" or longer)is to be inst_led, de not use the nipple and co_ng
InStallTemperalu_Pressurep_otectNeeou_nent _quired by _c_.aleodes,b_ notlessthan a comb+ha.
bo,, Temperature Pressure Relief Valve certified as meeting the requi;ements for Relief Valves and
AutomaticGas Shutoff_
mg lab_aton/that _ periodc_specaca ofpn:ducbt_ol Im_:l equprnemor marshalsTheva;ve
rn_ beode_l_, pmV,ded _€_hM:ing, c<_ mstal_d soI_ d_so3an_ecanexatonlyw_n 6 _ch_s
above,ot at
See rnar_Jalheading-
9