SYSTEM COMPONENT PART
TABLE 1:
Item | Component | Function |
1 | Solar collector | Absorbs the sun’s heat energy and transfers this to the heat transfer |
|
| fluid circulating through the collector |
2 | Solar storage tank | Stores potable water heated by solar generated heat or installed |
|
| |
3 | Heat exchanger (Not Shown) | Transfers the heat from the collector loop to the potable water in the |
|
| solar storage tank |
4 | Expansion tank | Allows for the expansion and contraction of the heat transfer fluid as |
|
| it heat and cools. |
5 | Temperature and Pressure relief | Required by plumbing code to automatically open and dump water if |
| valve | the storage tank exceeds 150 PSI of pressure or 210° F in tempera- |
|
| ture |
6 | Air vent | Purges air from the collector loop fluid during the installation and is |
|
| shut off later on to prevent glycol losses in steam phase. |
7 | Drain valve | Used to drain the heat transfer fluid from the collector loop |
8 | Mixing valve | Used to temper hot water from the solar storage tank with cold inlet |
|
| water to maintain appropriate temperature hot water delivered from |
|
| the system |
9 | Solar pump station | Controls the flow of heat transfer fluid from the collectors to the tank/ |
|
| heat exchanger. For a detailed description of the solar pump station |
|
| see page 20. |
10 | Temperature sensor | Tank and collector sensor work together to turn the circulating |
|
| pump(s) on and off at preset temperature differentials |
|
| |
| STORAGE TANK INSTALLATION | |
|
|
|
Never operate the electrical heating element without being certain the solar water heater is completely filled with water. If any air is left in the top of the tank, the heating element will burn out.
LOCAL CODES
The installation of this solar water heater must be in accordance with these instructions and all applicable local codes and electric utility requirements. In the absence of local codes, install in accordance with the latest edition of the National Electrical Code
TEMPERATURE-PRESSURE RELIEF VALVE
For protection against excessive pressures and temperatures in this water heater, install
Install the
In cold climates, it is recommended that the discharge pipe be terminated at an adequate drain inside the building. Be certain that no contact is made with any live electrical part. The discharge opening must not be blocked or reduced in size under any circumstances. Excessive length, over 15 feet, or use of more than two elbows can cause restriction and reduce the discharge capacity of the valve.
No valve or other obstruction is to be placed between the
The Discharge Pipe:
•Shall not be smaller in size than the outlet pipe size of the
•Shall not be plugged or blocked.
•Shall be of material listed for hot water distribution.
•Shall be installed so as to allow complete drainage of both the
•Must terminate a maximum of six inches above a floor drain
7