c a l l t o d a y 0 1 2 1 4 7 2 0 3 6 1 o r e - m a i l i n f o @ c r a n l e a . c o . u k

SERVOMEX

5Servomex 1440 Oxygen & Carbon Dioxide analyser

Provides high performance measurement of gases, available in single modules measuring either Oxygen or Carbon Dioxide or dual version measuring both.

Also available as a fast response analyser, with a response time of <200msecs at 150ml/min.

Accuracy

02 ± 0.1%

C02 ± 0.1%

5

Order codes

1440

O2/CO2 analyser - with sample pump

1440 CO2

CO2 analyser - with sample pump

1440 O2

O2 analyser - with sample pump

1440SP

Sample pump for 1440 analyser fitted

1440FR

Fast response O2/CO2 analyser with sample pump

6Servomex 5200 Multi Purpose analyser

Suitable for measuring levels of Oxygen, Methane, Carbon Dioxide and Carbon Monoxide. It has a range of sampling and power options to suit individual needs.

Available with a choice of two paramagnetic oxygen transducers (standard and high accuracy). They both offer

fast, selective measurement of Oxygen, without the disadvantage of electro-chemical or zirconia cells.

Accuracy

02 ± 0.1%

CO2 ± 0.1%

Order codes

 

5200S

O2/CO2

analyser - standard

 

5200HA

O2/CO2

analyser - high accuracy

 

5200/02

O2

analyser - standard

 

5200HA/02

O2

analyser - high accuracy

 

5200/C02

CO2 analyser - standard

6

Factory fitted options

 

5200 BAT

Rechargeable internal battery

 

5200 OUT

4 - 20 mA output per channel

WOODWAY

7Woodway iMETT

Now everyone can experience the benefits of VO2 testing. The iMETT from Woodway is an easy to use, inexpensive metabolic testing system that evaluates and monitors aerobic fitness by determining each individual’s anaerobic threshold.

Create individualised weight loss or aerobic fitness programmes and incorporate the iMETT assessment into existing training packages.

Each iMETT program includes

VE analyser with software to determine cardio programmes

Design testing protocols

Additional fitness assessments

Other fitness evaluations are based on predictions, estimates and outdated charts. We’re all familiar with 220 minus age – but these programmes have large margins of error and a history of unreliable results.

Determine a true heart rate training zone with a precise submax VO2 test. From the data you’ll be able to provide customised

7exercise prescriptions that can help athletes reach their exercise goals quickly and safely.

Order code iMETT

metabolic measurement

63

Page 67
Image 67
Diamondback Lode Valiant Treadmill Metabolic measurement, Servomex 1440 Oxygen & Carbon Dioxide analyser, Woodway iMETT