67
Appendix A:Specifications
This appendix provides NS9210 Processor Module and electrical specifications, as
well as module and development board mechanical specifications.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Environmental specifications

The module board assembly meets all functional requirements when operating in
this environment:
Operating temperature: -40°C to +85°C
Storage temperature: -40°C to +125°C
Relative humidity: 5% to 95%, non-condensing
Altitude: 0 to 12,000 feet
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Mechanical specifications

The module size is 50 x 50mm.
Two board-to-board connectors are used on the module. The distance between the
module and the base board depends on the counterpart on the base board. The
minimum distance is 5mm.
The height of the parts mounted on the bottom side of the module should not
exceed 2.5mm. The height of the parts mounted on the top side of the module
should not exceed 4.1mm.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Safety statements

To avoid contact with electrical current:
Never install electrical wiring during an electrical storm.