4
MPS 409 Setup Guide (Continued)
Extron USA - West
Headquarters
+800.633.9876
Inside USA/Canada Only
+1.714.491.1500
+1.714.491.1517 FAX
Extron USA - East
+800.633.9876
Inside USA/Canada Only
+1.919.863.1794
+1.919.863.1797 FAX
Extron Europe
+800.3987.6673
Inside Europe Only
+31.33.453.4040
+31.33.453.4050 FAX
Extron Asia
+800.7339.8766
Inside Asia Only
+65.6383.4400
+65.6383.4664 FAX
Extron Japan
+81.3.3511.7655
+81.3.3511.7656 FAX
Extron China
+400.833.1568
Inside China Only
+86.21.3760.1568
+86.21.3760.1566 FAX
Extron Middle East
+971.4.2991800
+971.4.2991880 FAX
© 2010 Extron Electronics All Rights Reserved. www.extron.com
68-1833-50
Rev. A
07 10
Setting the Microphone Talk-Over Threshold
Microphone threshold (the volume where vocal audio is detected) and the program audio level during talkover are adjustable via SIS
commands. See Audio Adjustments in the MPS 409 User Guide for additional SIS commands.
1. Speak into the microphone in a normal voice. The main program audio level should drop moderately. If not, adjust the microphone
threshold level.
2. Stop speaking into the microphone. Main program audio should recover to its previous level after approximately four seconds. If
not, adjust the microphone threshold level.
3. If the program audio during talkover is too loud, or too soft, adjust the program audio level.
Mic talk-over threshold
Display talk-over threshold X* * 2 # Thr X* ] Shows the mic threshold
number. X* = 0 through 15,
default = 8.
Decrement threshold – * 2# Thr X* ] Decrements mic threshold one
step.
Increment threshold + * 2# Thr X* ] Increments mic threshold one
step.
View mic talk threshold 2 # X* ]