3.Locate the owner’s packet inside in equipment compartment (plastic bag with parts and manual). Inside the bag is a plastic hose bib.

4.Screw the hose bib onto the male fitting located at the bottom of the hot tub on the pedestal, to the lower right of the equipment compartment.

5.Close the valve on the side of the hose bib and screw the cap onto the end of the hose bib.

6.Check the pump unions to be sure that they are tight to prevent the possibility of leakage in the equipment compartment.

7.Fill your spa with water up to 6"(15.24 cm) below the lip of the spa.

8.Turn on the circuit breaker. One minute after the power is turned on, the spa will automatically begin its first, one hour filtration cycle. Let the system run for 30 to 45 seconds to prime the pump. On two pump models, Pump 2 will operate on high speed for the first minute of each filter cycle. If there is no jet action, then the water level is too low or there is air trapped in the plumbing lines. To eliminate the trapped air, turn off the pump(s) and loosen the top pump union slightly to let the air escape. Re-tighten the pump union and turn on the pump again.

9.Your spa will automatically filter itself twice each day. At the beginning of each filtration cycle, the pump will run on high speed for 5 minutes and then on low-speed for the remainder of the filter cycle. The second filtration cycle will begin twelve hours after the start of the first. To reset the start of these cycles, simply turn off power to the spa by opening the circuit breaker box, turn the breaker off, and then turn it back on. This resets the filtration cycle to start one minute later. Or follow the procedure outlined in “Number of Filter Cycles" and “Filter Cycle Duration”. The filter cycle LED indicator will be on when there is a filter cycle is running.

10.A thermostat controls the spa temperature. Whenever there is a call for heat, your spa will turn on the heater and the pump will run at low speed as necessary to maintain the temperature. Push the UP pad until

the desired temperature is indicated on the display screen. In a few seconds, the screen will start displaying the current spa water temperature again. The maximum temperature that can be set is 104°F (40° C). Heating will occur at the rate of 1 (0.55°C to 8° F (4.4° C) per hour.