Battery Information.

1.Unclip the battery cover on the back of the remote control. (See Fig. 7)

2.Install AAA batteries into the remote control.

3.Replace the battery cover.

Discard leaky batteries.

Dispose of batteries in the proper manner according to provincial and local regulations.

Any battery may leak electrolyte if mixed with a different battery type, if inserted incorrectly, if all the batteries are not replaced at the same time, if disposed of in a fire, or if an attempt is made to charge a battery not intended to be recharged.

Thermal safety cut-out

A thermal safety cut-out is incorporated in the fan stove to prevent damage due to overheating. This can happen if the heat outlet was restricted in any way or if the chimney flue has not been blocked off effectively. If the cut-out operates, unplug the stove from the socket outlet and allow approximately 10 minutes before reconnecting. Before switching the stove back on remove any obstruction that may be restricting the heat outlet, then continue normal operation.

Tips for using your appliance.

1.Only pull out the drawer when its time to refill the water tank or change a lamp, otherwise it may lead to excess water in the sump and reduced flame effect. If this happens empty the water from the sump as instructed under ‘Maintenance’.

2.With the flame setting on minimum the unit will use approximately 40ml of water per hour and will last 3 times as long than when it is at maximum flame setting.

3.Do not tilt or move the stove while there is water in the tank or sump.

4.Make sure that the stove is on a level floor.

5.The flame control knob ‘C’ Fig. 2 may be turned up or down to give a more realistic effect.

6.Sometimes the flames appear more real when the flame control knob is turned down.

7.Give the flame generator some time to react to changes you may make on the flame control knob.

Maintenance

WARNING: ALWAYS DISCONNECT FROM THE POWER SUPPLY BEFORE ATTEMPTING ANY MAINTENANCE

Changing lamps.

If a large amount of the smoke appears grey or colourless it may be that one or more lamps have failed.

You can check for lamp failure as follows.

1.Leaving the flame effect on, open the doors fully, gently pull the drawer fully out by the tab. (See Fig. 3)

2.View the lamps from a distance in front of the stove and observe which lamp needs to be changed.

3.Put Switch ‘A’ in the ‘OFF’ position, and unplug the stove from the mains.

4.Leave the appliance for 20 minutes to allow the lamps to cool down before removing them.

5.Remove the water tank by lifting upwards and place in a sink.

6.Remove the sump as described in the Cleaning Section.

7.Remove the defective lamp, by gently lifting vertically and disengaging the pins from the lamp holder, (See Fig. 4 and 5). Replace with a Dimplex Opti-myst, 12V, 50W, Gu5.3 base, 8° beam angle, coloured lamp. (Purchased from www.dimplex.co.uk under the section ‘After Sales Service’, details of how to purchase the lamps are contained therein.)

8.Carefully insert the two pins of the new lamp into the two holes in the lamp holder. Push firmly in place. (See Fig. 4 and 5).

9.Replace the Sump and water tank and carefully close the drawer and doors.

10.Switch on.

Filling the water tank.

When the water tank is empty, flame and smoke effect shuts off, and you will hear 2 audible ‘beeps’. Follow these steps to refill:

1.Open doors.

2.Press Switch ‘A’ to (0) (See Fig. 2).

3.Open the doors fully and gently pull out the drawer as far as possible by the tab. (See Fig. 3)

4.Remove the water tank by lifting upwards and outwards.

5.Place the water tank in sink and remove cap, Anti- clockwise to open. (See Fig. 6)

6.Fill tank with filtered tap water only. This is necessary to prolong the life of the flame and smoke producing

unit.

The water should be filtered through a conventional domestic water filter unit and the filter should be replaced regularly.

7.Screw the cap back on, do not overtighten.

8.Return the tank to the sump, with the tank cap facing down and the flat side of the tank facing outward.

9.Gently push the drawer back in as far as it will go.

10.Press Switch ‘A’ to ‘ON’ ( I ) position (See Fig. 2)

11.Press Switch ‘B’ once to turn on flame effect. (See manual control section and Fig. 2)

- 3 -

Page 9
Image 9
Dimplex EN60555-2 Battery Information, Discard leaky batteries, Thermal safety cut-out, Tips for using your appliance

EN60555-3, EN60555-2, EN55014 specifications

Dimplex is a brand renowned for its commitment to innovation and efficiency in electric heating solutions. Among its product offerings, the Dimplex EN55014, EN60555-2, and EN60555-3 stand out for their adherence to rigorous standards and advanced technologies.

The Dimplex EN55014 is designed primarily for electrical appliances, ensuring they comply with essential electromagnetic compatibility requirements. This standard ensures that the appliance does not interfere with other electronic devices while maintaining optimal performance. This is crucial in today's interconnected environment, where multiple devices operate in close proximity. The EN55014 certification guarantees that Dimplex products remain reliable, fostering consumer confidence in their usage.

Moving on to the EN60555-2 standard, it focuses on reducing the harmonic currents generated by electrical equipment. Harmonics can lead to inefficiencies and potential damage to electrical networks. The Dimplex range offers solutions that are designed to minimize these harmonics, contributing to improved system stability and reducing energy losses. By complying with this standard, Dimplex products promote a cleaner energy environment, which is essential for both residential and commercial applications.

The EN60555-3 standard extends the assessment of harmonics, specifically addressing the limits of voltage distortion in public power systems. This is vital to ensure that the power supply remains stable and reliable. Dimplex products have incorporated technologies that keep them well within these limits, ensuring minimal disturbance to the wider electrical grid. This feature is particularly significant for businesses and infrastructures reliant on consistent power levels, as it helps prevent outages and equipment failure.

In summary, the Dimplex EN55014, EN60555-2, and EN60555-3 certifications represent a commitment to quality and efficiency. By focusing on electromagnetic compatibility and minimizing harmonic distortions, Dimplex ensures that its products not only excel in performance but also contribute positively to the broader electrical ecosystem. These features make Dimplex an ideal choice for consumers and commercial operators looking for reliable, innovative heating solutions that prioritize sustainability and efficiency. Dimplex continues to lead in implementing standards that protect both users and the environments in which they operate.