11 Device Information
1Type and order code
2Design
2.1Model
2.2Degree of protection according to EN 60 529 for compact devices and heating components
2.3Installation Location
3 | Performance data |
|
3.1 | Operating temperature limits: |
|
|
|
|
| Heating water flow/return flow 1 | °C / °C |
| Cooling, flow | °C |
|
|
|
| Air (heating) | °C |
| Air (cooling) | °C |
3.2Temperature spread of heating water at A7 / W35
3.3 | Heat output / COP | at | kW / | |||
|
| at | kW / | |||
|
| at A2 | / W35 2 | kW / | ||
|
| at A7 | / W35 | 2 | kW / | |
|
| at A7 | / W45 | 2 | kW / | |
|
| at A10 / W35 2 | kW / | |||
3.4 | Temperature spread of cooling water at A35 / W7 |
| ||||
3.5 | Cooling capacity / COP | at A27 / W7 |
| kW / | ||
|
| at A27 | / W18 | kW / | ||
|
| at A35 | / W7 |
| kW / | |
|
| at A35 | / W18 | kW / | ||
|
|
|
|
|
|
|
3.6 | Sound power level |
|
|
|
| dB(A) |
3.7 | Sound pressure level at a distance of 1 m (indoors) | dB(A) |
3.8Heating water flow with an internal pressure differential of m³/h / Pa
3.9Cooling water flow with an internal pressure differential of m³/h / Pa
3.10 | Air flow rate with an external static pressure differentia | m³/h / Pa |
|
| m³/h / Pa |
|
|
|
3.11 | Refrigerant; total filling weight | type / kg |
4 | Dimensions, connections and weight |
|
|
|
|
4.1 | Device dimensions | H x W x L cm |
4.2 | Device connections to heating system | Inch |
4.3Device connections to additional heat exchanger
| (waste heat recovery) |
| Inch |
4.4 | Air duct inlet and outlet (min. internal dimensions) | L x W cm | |
|
|
| |
4.5 | Weight of the transportable unit(s) incl. packing | kg | |
5 | Electrical connection |
|
|
|
|
|
|
5.1 | Nominal voltage; fuse protection |
| V / A |
5.2 | Nominal power consumption 2 | A2 W35 | kW |
5.3 | Starting current with soft starter |
| A |
5.4 | Nominal current A2 W35 / cos ϕ |
| A / |
6Complies with the European safety regulations
7Additional model features
7.1Defrosting
Type of defrosting Defrosting tray included
7.2Heating water in device protected against freezing
7.3Performance levels
7.4Controller internal/external
LI 11TER+
Reversible
IP 21
Indoors
Up to 58 / above 18
+7 to +20
9.7 |
| 5.0 |
7.1 / 2.9 |
| 6.6 / 2.7 |
|
| 6.4 / 2.3 |
8.8 / 3.2 |
| 8.8 / 3.1 |
11.3 / 3.8 |
| 11.3 / 3.6 |
|
| 9.6 / 3.1 |
12.2 / 4.1 |
| 12.1 / 3.9 |
6.5 |
| 5.0 |
8.8 / 2.8 |
| 8.8 / 2.8 |
10.9 / 3.3 |
| 10.8 / 3.2 |
7.6 / 2.1 |
| 7.5 / 2.1 |
9.5 / 2.5 |
| 9.5 / 2.5 |
| 55 / 61 | |
| 50 | |
1.0 / 3000 |
| |
| 1.9 / 10900 | |
1.0 / 3000 |
| 1.3 / 5900 |
|
|
|
4200 / 0
2500 / 25
R404A / 5.1
136 x 75 x 88
G 1 1/4'' external G 1 1/4'' external
50 x 50
222
400 / 16
2.742.86
| 23 | |
4.9 / 0.8 |
| |
| 5.16 / 0.8 | |
| 3 |
Automatic
Reverse cycle Yes (heated)
Yes4
1
Internal
LI 16TER+
Reversible
IP 21
Indoors
Up to 58 / above 18
+7 to +20
+15 to +40
.9..3 |
| 5..0 |
10.6 / 3.0 |
| 10.5 / 2.9 |
|
| 9.9 / 2.5 |
12.8 / 3.4 |
| 12.7 / 3.2 |
15.1 / 3.8 |
| 14.9 / 3.6 |
|
| 14.7 / 3.3 |
16.7 / 4.1 |
| 16.6 / 3.9 |
6.6 |
| 5.0 |
12.6 / 2.6 |
| 12.5 / 2.6 |
16.4 / 2.8 |
| 16.4 / 2.8 |
10.7 / 2.0 |
| 10.6 / 2.0 |
14.3 / 2.3 |
| 14.3 / 2.2 |
| 57 / 62 | |
| 52 | |
1.4 / 4500 |
| |
| 2.6 / 14600 | |
1.4 / 4500 |
| 1.8 / 7000 |
|
|
|
5200 / 0
4000 / 25
R404A / 5.7
157 x 75 x 88
G 1 1/4'' external
G 1 1/4'' external
57 x 57
260
400 / 20
3.84.0
| 25 | |
6.9 / 0.8 |
| 7.2 / 0.8 |
| 3 | |
|
|
|
Automatic
Reverse cycle
Yes (heated)
Yes4
1
Internal
English
1.See operating limits diagram
2.This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, other parameters, such as, in particular, the defrosting capacity, the bivalence point and regulation, should also be taken into consideration. The specified values, e.g. A2 / W55, have the following meaning: 2 °C external air temperature and 55 °C heating water flow temperature.
3.See CE declaration of conformity
4.The heat circulating pump and the heat pump controller must always be ready for operation.