Dimplex Optiflame Electric Fireplace Manual Controls, Resetting The Temperature Cutout Switch

Models: Optiflame Electric Fireplace

1 12
Download 12 pages 37.32 Kb
Page 7
Image 7
B. Remote Control Usage

FIGURE 3

NOTE

Hot air will blow from both sides of the fireplace when the heater control switch is activated

CAUTION

If you need to continuously reset the heater, disconnect the power at the main service panel and call your local dealer.

NOTE

The heater may emit a slight, harmless odor when first used. This odor is a normal condition caused by initial heating of internal heater parts and will not occur again.

B. Remote Control Usage

The remote control operates the fireplace levels sequentially. The level is increased every time the ON button on the transmitter is pressed. The fireplace can be turned off at any point by pressing the OFF button on the remote control transmitter.

Level 1: The flame effect is turned on and the first red indicator light is activated.

Level 2: The flame effect remains on, the heater is activated to the low heat setting, and the first and second red indicator lights are activated.

Level 3: The flame effect remains on, the heater is set to the high heat setting, and all three red indicator lights are activated.

MANUAL CONTROLS

The fireplace can also be controlled in a similar manner to the remote control with switches located on the fireplace (FIGURE3).

A.Main Power Switch

Main on/off switch, supplies power to the remote control receiving unit. When placed in the on position level 1 indicator will flash.

B.Heater Control Switch

Operates fireplace in the same manner as the remote control transmitter. Pressing the left side of this switch has the same effect as the ON button on the remote control and the right side has the same effect as the OFF button of the remote control. Pressing once to the left activates Level 1, twice activates Level 2, three times activates Level 3. Pressing to the right turns the fireplace off.

RESETTING THE TEMPERATURE CUTOUT SWITCH

The heater on this fireplace is protected with a safety device to prevent overheating. Should the heater overheat, an automatic cut out will turn the heater off and it will not come back on without being reset. It can be reset by switching the Main Power switch (FIGURE 3) to OFF and waiting 5 minutes before switching it to ON. The remote control will need to be re-initialized (see page 2)

4

Page 7
Image 7
Dimplex Optiflame Electric Fireplace Manual Controls, Resetting The Temperature Cutout Switch, B. Remote Control Usage